Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock
All best sellers
  • PAYMENT METHODS

LAQUA‐EC220 Handheld Conductivity/Resistivity/Salinity/Total  MYJ
  • LAQUA‐EC220 Handheld Conductivity/Resistivity/Salinity/Total  MYJ
  • LAQUA‐EC220 Handheld Conductivity/Resistivity/Salinity/Total  MYJ
  • LAQUA‐EC220 Handheld Conductivity/Resistivity/Salinity/Total  MYJ
  • LAQUA‐EC220 Handheld Conductivity/Resistivity/Salinity/Total  MYJ

EC220 Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

EC220

EC220 Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

Only the Meter

EC220-K

Package Details:

  • LAQUA EC220 Conductivity/Resistivity/Salinity/TDS/Temperature meter
  • 2 x AA batteries
  • Manual and quick guide
  • 9383-10D plastic-body, Ti/Pt black conductivity probe (k=1.0) integrated with temperature sensor
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions (60ml each)
  • Carrying case
CHOOSE MODEL
€330.00
VAT excluded
Quantity

Description
  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Automatic/manual temperature compensation and temperature calibration function
  • Conductivity and Total Dissolved Solids (TDS) conversion
  • Four (4) TDS calibration curves for a wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) Salinity calibration curves: NaCl, Seawater
  • Temperature readings in °C and °F
  • With real-time clock and date/time stamp for GLP compliance
  • Automatic data logging; Built-in memory can store up to 1000 data
  • Real-time, auto-hold and auto-stability measurement modes
  • Auto power off (programmable: up to 30 minutes)
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output to connect the meter to computer via USB PC cable for data collection and to printer via RS232 cable for printing
  • Powered by 2 x AA batteries
  • Housing is water and dust resistant, shock and scratch resistant, anti-slip, IP67 rated
  • Packaged with electrodes and calibration solutions in a carrying case
  • 3 years meter warranty
Conductivity Range ...µS/cm to 200.0 mS/cm (k=1.0)
Resolution 0.05% full scale
Accuracy ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm 
Reference Temperature 15 to 30 °C (adjustable)
Temperature Coefficient 0.00 to 10.00% (adjustable)
Cell Constant 0.1, 1.0, 10.0 (adjustable)
Calibration Points Up to 4 (Auto) / Up to 5 (Manual)
Measurement Unit S/cm, S/m (selectable / auto-ranging)
TDS Range ...ppm to 100 ppt (TDS factor=0.5)
Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L)
Accuracy ±0.1% full scale
TDS Curves Linear (0.40 to 1.00), EN27888, 442, NaCl
Resistivity Range 0.000 Ω•cm to 20.0 MΩ•cm
Resolution 0.05% full scale
Accuracy ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm
Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 %
Resolution 0.1 ppt / 0.01%
Accuracy ±0.2% full scale
Salinity Curves NaCl / Seawater
Calibration Option Yes
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F 
Accuracy ± 0.5 °C / ± 0.9 °C
Calibration Option Yes
Memory Data 1000
Auto Log Data Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable, Auto Hold, Real Time
Auto-Shut Off Yes (Programmable: up to 30 minutes)
Electrode Status Yes (On screen display)
Diagnostic Messages Yes
Software Upgrade Yes via PC (USB) cable PN 3200779639
PC Communication Yes via PC (USB) cable PN 3200779639
Printer Communication Yes via Printer (RS232) cable PN 3200779638
Meter Inputs BNC (for conductivity electrode), phono (for temperature sensor)
Meter Output phono (for PC/printer connection)
Display Custom LCD with backlight
Housing IP67, shock & scratch resistant, non-slip
Power Requirement 2 x AA batteries 
Battery Life > 500 hours
Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm
Meter Weight  Approx. 260g (with batteries) / 216g (without batteries)
Product Details
EC220
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: RSTAR Affinity Tilt Logger

RSTAR Affinity Tilt Logger

(0)
Product Features Low Power Wide Area Network communications using LoRa technology Robust, compact design with IP68 weatherproofing Internal and external antenna options  Seamless integration with Affinity Data Platform
More
In stock

Reference: RK600-07B

Brand: RIKA SENSORS

RK600-07B Data Logger of Automatic Weather Station

(0)
RK600-07B Data Logger of Automatic Weather Station Data Logger with Software LCD: 7" Color touch screen Internal storage: 64M Shell material: ABS Data interface: RS485 Supply: 12VDC, 100- AC220V adapter Record interval: 1min-240min adjustable Power consumption: 5W max. Sensor conection max.: 20 sensors interface
More
In stock

Reference: M1220

Brand: COMET

M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 Thermocouple inputs

(0)
 M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 Thermocouple inputs Universal datalogger with 4 inputs. Two inputs for temperature-humidity probes and two inputs for thermocouples K, J, S, B, T, N.Multilogger can be installed permanently to Ethernet network or work as portable device.Included is traceable calibration certificate in accordance...
More
In stock

Reference: 67130020

Brand: FUEL CELL

Flow Battery Flex-Stak

(0)
Flow Battery Flex-Stak The Flex-Stak is a fully assembled, tested, and ready-to-use flow battery! Only a flat-head screwdriver and torque wrench are needed to assemble the Flex-Stak, so you can focus on creating your own electrical applications.
More
In stock

Reference: CD4

Brand: BOSEAN

CD4 Mining Use Multi-gas Detector

(0)
CD4 Mining Use Multi-gas Detector The CD4 mining use multi gas detector adopts large-scale integrated circuit technology and complies with international intelligent technology standards. This detector uses catalytic and electrochemical gas sensors to detect gases through natural diffusion, with excellent sensitivity and repeatability. Convenient use and...
More
In stock

Reference: RXW-RGF-868

Brand: ONSET

RXW-RGF-868 Davis HOBOnet Rainfall (metric) Sensor

(0)
RXW-RGF-868 Davis HOBOnet Rainfall (metric) Sensor A wireless sensor that records rainfall in 0.2 millimeter increments; communicates data to the HOBO RX3000 or the HOBO MicroRX station; preconfigured and ready to deploy.Important InformationA complete system requires at least one HOBO RX3000 Remote Monitoring Station, a HOBOnet Wireless Manager, and a...
Price €530.00
More
In stock

Reference: SN-500-SS

Brand: Apogee Instruments

SN-500-SS Net Radiometer

(0)
SN-500-SS Net Radiometer Apogee Instruments' new four-component net radiometer provides individual measurement of net radiation components. The sensor features an SDI-12 output, eliminating the need for multiple analog channels to
Price €4,910.00
More
In stock

Reference: TRSYS20

Brand: Hukseflux

TRSYS20 Thermal resistance Measuring System

(0)
TRSYS20 Thermal resistance Measuring System TRSYS20 is a high-accuracy measuring system used in determining the in-situ thermal resistance (R-value), thermal conductance (Λ-value), and thermal transmittance (U-value) of building envelope components. The system is mostly used for measurements according to standard practices of ISO 9869, ASTM C1046 and ASTM...
More
In stock

Reference: V5D (2G-60)

Brand: FRIGGA

V5D (2G-60) Real-time Temperature Positioning Monitor (Single-use)

(0)
V5D (2G-60) Real-time Temperature Positioning Monitor (Single-use) InformationTemperature, Weak Light, LocationNew generation of global real-time temperature monitorData is stored in the cloud for traceability; USB port for backup PDF data downloadFull cold chain visibility(Location, Temperature, Light, Route) via Frigga cloudImprove transportation...
More
In stock

Follow us on Facebook