RK200-02 Quantum PAR Sensor , Photosynthetic Active Radiation Sensor
PAR Sensor
Spectral range: 400~700nm
Range: 0-2500μ*mol/m2*s
Accuracy:±5% rdg
Output signal: 0-2V/0-5V/4-20mA/RS485 Power supply: 12-
The RK200-02 PAR Sensor is mainly used for measuring solar radiation within 400~700nm wavelength. It is easy installation and can work continuously in all weathers. When there is sunlight, voltage output proportional to incident light intensity will be generated by the silicon-photo detector in the sensor. Its sensitivity is proportional to the cosine of incident light direct angle. Each product is with one sensitivity coefficient respectively. It can directly output radiation value in unit of μ*mol/m2*s.
Available models |
|
RK200-02A | RK200-02B |
PAR Sensor | PAR Sensor |
Spectral range: 400~700nm | Spectral range: 350~1100nm |
Range: 0-2500μ*mol/m2*s | Range: 0-2000W/m2 |
Accuracy: ±5% reading | Accuracy: ±5% reading |
Output signal: 0-2V/0-5V/4-20mA/RS485 | Output signal: 0-2V/0-5V/4-20mA/RS485 |
Power supply: 12-24 VDC | Power supply: 12-24 VDC |
SPECIFICATIONS |
||||
Item
|
Specification | |||
Spectral range | 0-2500μ*mol/m2*s | 400-700nm | ||
0-2000W/m2 | 350-1100nm | |||
Supply | 5V,12-24VDC | |||
Accuracy | ±5% rdg | |||
Range | 0-2500μ*mol/m2,0-2000W/m2 | |||
Output | 0-2000mV | 4-20mA(2-wires) | RS485 | |
Sensitivity | 0-2500μ*mol/m2*s | 0.8mV/μmol*m-2* S-1 | 6.4μA/μ*mol*m2*s | / |
0-2000W/m2 | 1mV/W/m2 | 8uA/W/m2 | / | |
Response time | <1s (99%) | |||
Temperature effect | <0.05%/℃ | |||
Cosine correction | <10% (until 80°) | |||
Non-linearity | <±2% | |||
Operating temperature | -40℃-+80℃° | |||
Shell material | Aluminum alloy | |||
Storage Condition | 10℃-60℃@20%-90%RH |
OUTPUT CHARACTERISTICS
0-2000mV
Range:0-2000W PAR values(W)= Voltage output value(μV)/1000
Range:0-2500μ*mol/m2*s PAR values(μ*mol/m2*s)= Voltage output value(μV)/800
4-20 mA
Range:0-2000W PAR values(W)=(I(μA)-4000μA)/8 (Where I is output current value,unit:μA )
Range:0-2500μ*mol/m2*s PAR values(μ*mol/m2*s)= (I(μA)-4000μA)/6.4(Where I is output current value,unit:μA )
RS485
MODBUS-RTU
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: DLI-500
Brand: Apogee Instruments
Reference: AT-100 microCACHE
Brand: Apogee Instruments
Reference: SFL
Reference: RX3004-SYS-KIT-813
Brand: ONSET
Reference: SQ-100X-SS
Brand: Apogee Instruments
Reference: ZL6 BASIC
Brand: METER GROUP
Reference: SR05-LI19
Brand: Hukseflux
Reference: RK200-05
Brand: RIKA SENSORS
Reference: RK200-03
Brand: RIKA SENSORS
Reference: H21-USB
Brand: ONSET
Reference: U30-NRC-SYS-C
Brand: ONSET
Reference: RX2101+SP-611
Brand: ONSET
Reference: DLI-400
Brand: Apogee Instruments
Reference: RK200-08
Brand: RIKA SENSORS
Reference: U30-NRC-000-10-S100-000
Brand: ONSET
RK200-02 Quantum PAR Sensor , Photosynthetic Active Radiation Sensor
PAR Sensor
Spectral range: 400~700nm
Range: 0-2500μ*mol/m2*s
Accuracy:±5% rdg
Output signal: 0-2V/0-5V/4-20mA/RS485 Power supply: 12-
check_circle
check_circle