A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.
IMPORTANT INFORMATION
Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1).
HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
VH400 Soil Moisture Sensor Probe Specifications
Power consumption: < 13mA
Supply Voltage: 3.5V to 20 VDC.
Dimensions See drawing.
Power on to Output stable: 400 ms
Output Impedance: 10K ohms
Operational Temperature: -40ºC to 85ºC
Accuracy at 25°C: 2%
Output: 0 to 3V related to moisture content
Shell Color: Red
Voltage Output Curves: Curves, Piecewise...
AD/A Surface Mount Atmospheric and Barometric Air Pressure Transducer, 0-10 V or 4-20 mA
500...1150 mbar
menu input altitude above sea level
0-10V, 4-20mA
hinge lock technology
FS1309 Oxygen Transducer for surface mounting, Modbus RTU
The device is designed for indoor use or in protected outdoor areas.
0...25% vol. optional 0...100% vol.
Modbus RTU, relay
LCD-Display
hinge lock technology
FS1600 Multi-Sensor Measuring Device with up to 8 sensors for surface mounting, with display, Modbus RTU
Multi-Sensor Measuring Device with up to 8 sensors for surface mounting, with display, Modbus RTU
Up to 8 measured variables in one device
Choice of 16 sensors
Modbus RTU
high quality case and stainless steel taps
hinge lock technology
CO2-M/A Air Quality Transducer for CO2, humidity, temperature in room housing, 0-10 V
0-2000/5000/10000 ppm
Mixed gas VOC
Temperature, humidity
0-10 V, relay
LCD display
FS4309 Air Quality Transducer for oxygen for surface mounting, 0-10 V
The device is designed for indoor use or in protected outdoor areas.
0...25% vol. optional 0...100% vol.
active output, 0-10 V
LCD-Display
hinge lock technology
Air Flow Transducer for laminar air flow, volume flow, temperature for duct mounting, with display, with changeover contact, 0-10 V or 4-20 mA
0-5 m/s, 0...+50°C
0-10 V, 4-20 mA
LCD display, relay
5 scales per device
Hinge locking technology
KLT/A Air Quality Transducer for mixed gas VOC, temperature for duct mounting, with display, with changeover contact, 2 x 0-10
0...100% VOC gas mixture, 0...+50 °C
0-10 V, relay
automatic recalibration
optional LCD display
hinge locking technology
RL2/A-UI Air Quality Transducer for Mixed Gas VOC in Room Housing, 10 LED traffic light, 0-10 V or 4-20 mA
0...100% mixed gas VOC
0-10 V, 4-20 mA, changer
automatic re-calibration
Output VOC:
0-10 V, 4-20 mA
0-10 V, 4-20 mA + changer
Supply voltage:
24 V AC/DC
Version:
LED display
UG-5-AFR-24V Smoke Detector for Air Ventilation Ducts
VdS, CE, DIBt
Built-in control unit (stand alone)
2 alarm relays, 1 service alarm, 1 system error relay, 1 low-flow relay, Modbus
Quick and simple installation
Flow indicator with high sensitivity
4 install positions 0, 90, 180 and 270°
Test hole in cover
Included
ST2 - Venturi pipe for duct smoke...