LAQUAtwin NO3‐11 Nitrate Ionometer
This is a nitrate meter used in a wide variety of analyses and measurements. It measures nitrate reliably and is very easy to use. It takes only a few seconds to give a result, making it an ideal instrument for field analysis.
Specifications:
Range: 6 to 9900 ppm.
Resolution: 1 - 100 ppm.
Accuracy: ±10% of reading value.
Calibration: 2 points.
Standard solution 30ppm.
Standard solution 150ppm.
Standard solution 300ppm.
Standard solution 2000ppm.
Standard solution 5000ppm.
Applications:
- Evaluation of nutrient concentration in soil.
- Evaluation of fertilization efficiency and crop nutrition.
- Sap analysis.
- Food analysis.
- Evaluation of river quality.
- Drinking water, fish tanks, etc.
These devices incorporate a flat ion electrode for microvolume measurement. The replaceable electrode uses the same measurement principle as the traditional nitrate ion selective electrode (ISE). They only require a few drops (0.3 ml) to provide a fast and accurate analysis.
It can be used as a traditional nitrate meter by immersing the electrode in a liquid.
An absorbent paper allows us to analyze micro samples from 50 µl.
Main features:
Temperature compensation.
Automatic calibration: recognizes calibration solutions. The user can choose calibrations at one or two points.
Detection of result stability.
Waterproof (IP67).
They do not use reagents.
Automatic selection of the appropriate range.
Automatic shut-off (30 minutes).
Different methods for measurement:
Immersion: You can analyze the sample in a beaker.
Sampling: Use it as a scoop to analyze the water.
Drops: LAQUAtwin meters can measure sample volumes as small as 0.05 ml by placing a drop of the sample on the sensor with a pipette.
Solid samples: Foods containing some moisture can be analyzed by placing a small piece directly on the sensor.
Powders: Simply place the powder sample on the sensor and pour the defined volume of deionized water on top.
Paper and textiles: If you want to analyze sheets of paper and textiles, cut the sample into small pieces and place them directly on the sensor. Pour the defined volume of deionized water on top.
Measurement in three easy steps:
1. Calibration: For a correct calibration, the sensor must be clean beforehand. If not, rinse with water and put some standard solution on the sensor and press the calibration button. A smiley face will appear indicating that calibration is complete. Clean the sensor with water until the calibration solution is removed and dry it with a soft, clean tissue.
2. Analysis: Only a tiny amount of sample is required, so just fill the sensor and wait a few seconds until the smiley face appears.
3. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1500 measurements or when calibration cannot be performed. Sensors are sold separately and can be easily removed and replaced.
This nitrate meter comes with:
2 CR2032 batteries, 1 pipette, Instruction Manual and Quick Start Guide.
Storage case.
150 ppm calibration solution (14 ml) and 2000 ppm calibration solution (14 ml).
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: LAQUAtwin pH-33
Brand: HORIBA LAQUAtwin
Reference: MQ21
Brand: Meatrol
Reference: ME-337
Reference: UA-002-64
Brand: ONSET
Reference: PP-500
Brand: Apogee Instruments
Reference: 57080205 1gr
Brand: FUEL CELL
Reference: TR-55i-P
Brand: TandD
Reference: TRC-24
Brand: Meatrol
Reference: LS173
Brand: LINSHANG
Reference: MX2302A
Brand: ONSET
Reference: TR-72nw-S
Brand: TandD
Reference: MX2306
Brand: ONSET
Reference: ME131M
Brand: Meatrol
Reference: LAQUA‐PH210‐K
Brand: HORIBA LAQUAtwin
Reference: ME238
Brand: Meatrol
check_circle
check_circle