Brand: iBUTTON MAXIM INTEGRATED
Specs:
Replacement electrode also available
Ref.: 86129
The pH-22 pH meter is supplied with:
Description
It is a pH meter used in a wide variety of analyzes and measurements. It measures pH reliably and very easy to use. It takes only a few seconds to give a result, making it an ideal instrument for analysis in the field.
This tool can be useful for decision making when carrying out quality inspections, since it provides an immediate evaluation of the pH value in many applications such as:
Uses:
- Fresh water analysis.
- Aquariums.
- Wastewater.
- Soil analysis for improved agriculture.
- Analysis of food freshness.
- Fermentation and brewing.
- Research laboratories.
- Quality controls of medical and cosmetic products.
- Preventive dentistry.
- School education.
These devices incorporate a flat ion electrode for measuring microvolumes. The replaceable electrode makes use of the same measurement principle as the traditional glass electrode. They only require a few drops (0.1 ml) to provide a fast and accurate analysis.
It can be used as a traditional pH meter by immersing the electrode in a liquid.
Main features:
Temperature compensation.
Automatic calibration: recognizes calibration solutions. The user can choose one or two point calibrations.
Detection of the stability of the result.
Waterproof (IP67).
Automatic selection of the appropriate range.
Automatic shutdown (30 minutes).
Different methods for measurement:
Immersion: You can analyze the sample in a beaker.
Sampling: Use as a shovel to test water.
Drops: LAQUAtwin meters can measure sample volumes as small as 0.05 ml by placing a drop of sample on the sensor with a pipette.
Solid samples: Foods containing some moisture can be tested by placing a small piece directly on the sensor.
Powders: Simply place the powder sample on the sensor and pour the defined volume of deionized water on top.
Paper and fabrics: If you want to analyze sheets of paper and fabrics, cut the sample into small pieces and place them directly on the sensor. Pour the defined volume of deionized water on top.
Measurement in three easy steps:
1. Calibration: For correct calibration it is necessary that the sensor be previously clean. If this is not the case, rinse it with water and put some standard solution on the sensor and press the calibration button. A smiley face will appear to indicate that the calibration is complete. Clean the sensor with water until the calibration solution is removed and dry it with a soft, clean tissue.
2. Analysis: You only need a tiny amount of sample, so you only need to fill the sensor and wait a few seconds for the smiley face to appear.
3. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1500 measurements or when calibration cannot be performed. Sensors are sold separately and can be easily removed and replaced.
Specifications
Model | pH-11 | pH-22 | pH-33 | |
Measurement Principle | Glass Electrode | |||
Minimum Sample Volume | 0.1ml (0.05ml with Sampling Sheet B) | |||
pH Range & Resolution | ||||
0.0 to 14.0 pH : 0.1 pH | • | |||
0.00 to 14.00 pH : 0.01 pH | • | • | ||
mV Range & Resolution | ||||
± 650 mV : 1mV | • | • | • | |
Calibration Points | ||||
Up to 2 | • | |||
Up to 3 | • | |||
Up to 5 | • | |||
Accuracy | ||||
±0.1 pH | • | |||
±0.01 pH | • | • | ||
Temperature Display | 0 to 50.0 °C | • | ||
Temperature Calibration | 5 to 40.0 ºC | • | ||
Display | Custom (monochrome) digital LCD with backlight | |||
Operating Temperature | 5 to 40°C | |||
Operating Humidity | 85% or less relative humidity (no condensation) | |||
Power | CR2032 batteries (2) | |||
Battery Life | Approx. 400 hours in continuous use (without backlight) | |||
Dimensions | 164 × 29 × 20mm (excluding projections) | |||
Mass | Approx. 55 g (including sensor and batteries) | |||
Functions | Auto Calibration | |||
Auto Buffer Recognition | ||||
Auto Temperature Compensation | ||||
Temperature Calibration (only for pH-33) | ||||
Auto Stable / Auto Hold Measurement | ||||
Auto Power Off (30mins) | ||||
Switchable Backlight | ||||
Low Battery Indicator | ||||
IP67 Dust / Waterproof |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: PX3PXN01S
Brand: VERIS
Reference: MP-100
Brand: Apogee Instruments
Reference: SU-220
Brand: Apogee Instruments
Reference: PX3PXN02S
Brand: VERIS
Reference: AM- 330
Brand: Apogee Instruments
Reference: RK210-03
Brand: RIKA SENSORS
Reference: TR-76Ui-S
Brand: TandD
Reference: HF03-LI19
Brand: Hukseflux
Reference: 300.021 No. PCB-9601
Brand: PRONAMIC
Reference: SO-120
Brand: Apogee Instruments
Reference: RK300-08
Brand: RIKA SENSORS
Reference: PX3ULX05
Brand: VERIS
Reference: SU-200-SS
Brand: Apogee Instruments
Reference: TR-74Ui-S
Brand: TandD
Reference: H722
Brand: VERIS
Reference: RXW-GP3A-868
Brand: ONSET
check_circle
check_circle