Gardon gauge water-cooled high heat flux sensor
GG01 is a water-cooled sensor that measures heat flux. The Gardon gauge sensor is based on copper and copper alloys, and works at heat flux levels at which other sensors get toasted. Optionally GG01 can be equipped with a sapphire window; to measure radiative heat flux only, and not convective heat flux. GG01 has an on-board thermocouple type K and is available with various dedicated measurement ranges.
Specifications
Measurand |
heat flux |
Measurement range |
(250, 500, 1000) x 10³ W/m² |
Measurand in SI units |
irradiance in W/m² |
Sensor technology |
Gardon |
Rated cooling water flow (see manual for more information) |
> 50 l/h (0.014 l/s) |
Nominal response time (63 %) at different rated measurement ranges |
: |
250 x 10³ W/m² |
250 x 10⁻³ s |
500 x 10³ W/m² |
200 x 10⁻³ s |
1000 x 10³ W/m² |
100 x 10⁻³ s |
Limiting measurement range |
150 % of rated measurement range |
Output signal |
DC voltage |
Output signal range |
> 5 x 10⁻³ V at rated measurement range |
Full field of view angle |
180° |
Calibration traceability |
to ITS-90 |
Calibration laboratory |
: |
-management system certification |
ISO 9001 |
-accreditation |
not accredited |
Calibration method |
secondary calibration method according to ISO 14934-3 |
Standard cable length |
2 m (see options) |
Order code standard version |
GG01/rated measurement range/cable length |
Options
Description
GG01 measures heat flux in the range of (250 to 1000) x 10³ W/m². Equipped with a black absorber, heat flux sensors of this type are designed for measurement in an environment in which heat flux is dominated by radiation. Using an open detector, GG01 is also sensitive to convective heat flux.
The GG01 Gardon gauge sensor, based on thermocouple materials, generates an output voltage proportional to the incoming irradiance. A type K thermocouple measures the body temperature. The sensor is water-cooled. Water cooling is usually supplied by tap water.
There are 3 versions of GG01; each with a different rated measurement range, sensitivity and response time. Irradiance ranges are (250, 500 and 1000) x 10³ W/m², for GG01-250, GG01-500 and GG01-1000 respectively. The body is equipped with a flange for easy mounting. GG01-250 may be equipped with a sapphire window. See options.
GG01 is made using oxygen-free high thermal conductivity copper and thin foils of a copper-nickel alloy. The sensor is called “Gardon gauge” after its inventor Robert Gardon. The benefit of this technology is that it can withstand very high heat fluxes.
Hukseflux invested in brand new manufacturing and test equipment for producing modern Gardon gauges. Each sensor is tested at its rated range.
All GG01s are tested to withstand a cooling water operating pressure of 10 bar.
Optionally GG01 may be equipped with a sapphire window (GG01-250-SW). It allows the user to measure only the radiative component of the heat flux.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: PX3UXX05
Brand: VERIS
Reference: DT2011B
Brand: RST
Reference: U0122
Brand: COMET
Reference: RTR-602EL
Brand: TandD
Reference: FS6003-MBR-A1B1H1R1T1W1W2-G
Brand: FUEHLER SYSTEME
Reference: PX3DLN02S
Brand: VERIS
Reference: TR-74Ui-S
Brand: TandD
Reference: EL1
Brand: MAE
Reference: GM2 Tempmate
Brand: tempmate
Reference: SQ-100X-SS
Brand: Apogee Instruments
Reference: DS9092K
Reference: PX3PXX01S
Brand: VERIS
Reference: RSTAR Affinity Tilt Logger
Reference: T3510+A1515eu
Brand: COMET
Reference: 57080237 1gr
Brand: FUEL CELL
check_circle
check_circle