Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock
All best sellers
  • PAYMENT METHODS

M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals
  • M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals

M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals

M1320

M1320 Multilogger - universal 4 channel Thermometer Hygrometer with 2 MiniDIN and 2 Terminals

Battery powered datalogger with 4 universal inputs for measurement of temperature, humidity, 0-10V voltage, 0-20mA current, two-state signal and for counting pulses.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.s portable device.

The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

Quantity

Description

Technical data

Measured value

Temperature

Relative humidity
Counted values (dew point…)
Current
Voltage
Two-state signal
Pulses

TEMPERATURE SENSOR - external probe Pt1000

Measuring range -200 to +600 °C
Accuracy ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C
Resolution 0.1 °C

TEMPERATURE+HUMIDITY SENSOR - external probe T+RH DIGI

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C

DEW POINT

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C

DC VOLTAGE

Measuring range 0 to 10 V
Accuracy ±10 mV
Resolution better than 100 µV

DC CURRENT

Measuring range 0 to 20 mA
Accuracy ±20 µA
Resolution better than 0,1 µA







BINARY SIGNAL

Input voltage for level “switched on”/ <0,4 V/> 2 V
Minimum/maximum input voltage 0 V/+30 V DC
I mpedance of the “switched on”/ < 10 kOhm/> 300 kOhm

COUNTER INPUT

Range of counter 24 bit (16 777 215) the counter overflow can be allowed
Maximum input frequency 200 Hz

GENERAL TECHNICAL DATA

  • Operating temperature: -10 to +60 °C
  • Channels: 2x external temperature probe or connectable temperature+humidity probe, 2x binary, counter, voltage and current input
  • Counted values: dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
  • Recording interval: 1s to 24 hours
  • Display and alarm refresh: each 10 s
  • Recording mode noncyclic: - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
  • Available temperature units: degrees Celsius, degrees Fahrenheit
  • Communication interface: Ethernet, USB, RS232
  • Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
  • Alarm protocols: E-Mail
  • Power AC: adapter 230Vac/5Vdc (neccessary for Ethernet interface)
  • Battery life: 3 - 4 weeks
  • Protection: class IP20
  • Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
  • Weight (including batteries): approx. 380 g
  • Warranty: 3 years.

Features

Up to 4 physical inputs - 2x TERMINALS + 2x MiniDin



  • Sensors with voltage output (range 0-10 V; accuracy ±10 mV)
  • Sensors with current output (range 0-20 mA; accuracy ±20 µA)
  • Devices with dual-state output (potential-free contact or 0-30 V voltage signal); can be applied to input 3 and 4
  • Devices with pulse signal (potential-free contact or 0-30 V voltage signal); can be applied to input 4
  • Pt1000 temperature probes with built-in configuration memory (xxx/M series)
  • Temperature/relative humidity probes with digital output - DigiS/M, DigiL/M, DIGIH/M
  • Probes are interchangeable without calibration to a specific device and regardless of cable length. Cable length can be 1, 2, 5, 10, 15 meters





Evaluation of up to 16 variables



Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be an additional expression of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can also be the result of conversions between channels, for example the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The recording mode can be set as non-cyclic, when the recording stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

Measured values ​​are displayed on the display with backlight option and possibility to change the size of the display digits
 



Power supply


Multilogger can be operated with an AC adapter or with rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and allow logging and measurement during a power failure. Thanks to the Ethernet output, the device reports the failure via an e-mail message.






Alarm limits and alarm indication

It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signaling can be acoustic (built-in acoustic alarm), optical, by sending an alert via e-mail or an alarm output. The alarm output is for connecting an external visual or audio alarm.









Communication interfaces
Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries. Multilogger - Alarm limits



  • Send an email when an alarm state starts or ends
  • Use DATALINK - display current values ​​or download values ​​from memory to the COMET database on your PC. COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
  • Simple wireless communication with TP-LINK Wi-Fi router
  • Third-party applications to read the actual measured values ​​using the universal SNMPv1 and XML protocols
  • Display the current measured values ​​using your web browser









ALARM OUT output

  • The output can be used to control other devices when the alarm is triggered, such as an external doorbell, telephone dialer, etc.
  • Output type: Open collector transistor
  • Maximum switching current: 100 mA
  • Maximum voltage at output: 24 V
  • Auxiliary voltage at terminal: +5 V (only when mains supply is present)
  • Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated via an internal buzzer, 3 LEDs or email alerts via the Ethernet port.

Product Details
M1320
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: RK100-02

Brand: RIKA SENSORS

RK100-02 Wind Speed Sensor

(1)
RK100-02 - Plastic Wind Speed Sensor Wind Anemometer Wind Speed Sensor Material: carbon fiber Test range: 0~45m/s Output signal: Pulses/4-20mA/0-5V/RS485 Supply voltage: 5V/12-24VDC
Price €125.00
More
In stock

Reference: UG-5-AFR-24V

Brand: FUEHLER SYSTEME

UG-5-AFR-24V Smoke Detector for Air Ventilation Ducts

(0)
UG-5-AFR-24V Smoke Detector for Air Ventilation Ducts VdS, CE, DIBt Built-in control unit (stand alone) 2 alarm relays, 1 service alarm, 1 system error relay, 1 low-flow relay, Modbus Quick and simple installation Flow indicator with high sensitivity 4 install positions 0, 90, 180 and 270° Test hole in cover Included  ST2 - Venturi pipe for duct smoke...
Price €445.00
More
In stock

Reference: SST

Brand:

SST Soil surface temperature sensor

(0)
Adjust the temperature of the floor surface at an adjustable height between 3 and 5 cm.Heat-resistant sensitive element Pt100 1/3DIN with four-wire connection.The sensitive element is protected by a series of panels against direct solar radiation and UV radiation, profiled arrangements that guarantee natural internal ventilation at ground level.On a...
More
In stock

Reference: PL200

Brand:

PL200 200 cm² Class A Rain Gauge

(0)
El pluviómetro Helmmann PL200 es un pluviómetro manual formado por un cuerpo cilíndrico de aluminio anodizado con una superficie de recogida de 200 cm² que recoge la lluvia en un recipiente de hasta 3 litros de capacidad (que corresponde a 150 mm) o directamente en un recipiente de clase A o A+ de 250 ml (250 cm3) equivalente a 12,5 mm de precipitación...
More
In stock

Reference: TR-50U2

Brand: TandD

TR-50U2 USB Compact Communication Interface for TR-5i Series Loggers

(0)
TandD TR-50U2 Comm Interfaces: USB, Optical Power: USB Bus Power Operating environment: Temperature: -10 to 60°C Humidity: less than 90%RH (No condensation) Do not use if the Data Logger is wet. Dimensions: H:80mm × W:56mm × D:16.5mm Accessories: USB Communication Cable, Software(CD-ROM), Manual The TR-50U2 is a communication cradle necessary for...
Price €225.00
More
In stock

Reference: 11060020 - 10x10

Brand: FUEL CELL

11060020 Platinum on Vulcan - Carbon Paper Electrode 0.3 mg/cm² 40%

(0)
A low-cost electrode utilizing a carbon fiber paper substrate and a 40% Platinum on Vulcan Carbon support catalyst.  This low loading is designed for cost sensitive applications and is suitable for electrochemical systems needing low amounts of Platinum to support the reaction.  This electrode is perfect for Hydrogen/Air Fuel Cell applications where the...
More
In stock

Reference: LS177C

Brand: LINSHANG

LS177C Coffee Colorimete

(0)
LS177C is a coffee colorimeter. It has a 7-inch touch screen, which is easy to use. The instrument can quickly match the closest SCAA number and HCCI to the measured coffee beans, and display the relevant coffee roast level. It also has color difference comparison function and color difference threshold can be set to achieve rapid QC testing. The...
Price €1,665.00
More
In stock

Reference: SU-220

Brand: Apogee Instruments

SU-220: USB output UV-A Sensor

(0)
SU-220: USB output UV-A Sensor The SU-220 UV-A, smart sensor can be connected directly to a computer (Windows or macOS X) via USB for taking spot measurements or graphing and datalogging real-time PPFD using the included software.
Price €625.00
More
In stock

Reference: U3631M

Brand: COMET

U3631M IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe

(0)
U3631M IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe GSM datalogger is designed to record temperature and humidity from built-in sensors and temperature from external probe. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the...
More
In stock

Reference: SpectraPen mini

Brand: Photon System Instruments (PSI)

SpectraPen mini Calibrated Spectroradiometer and Quantum Photometer

(0)
SpectraPen mini is a small, portable and affordable calibrated spectroradiometer and quantum light meter, which is controlled via mobile application. The SpectraPen mini measures spectral quality, light intensity and color. The device is calibrated for visible light in the range from 400 to 850 nm. The SpectraPen mini is ideal as a multi-purpose...
From Price €1,450.00
More
In stock

Reference: Na-11 LAQUAtwin

Brand: HORIBA LAQUAtwin

Na-11 LAQUAtwin Pocket Water Quality Meter

(0)
Na-11 LAQUAtwin Pocket Water Quality Meter The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the...
Price €365.00
More
In stock

Reference: M1323

Brand: COMET

M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals

(0)
M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals Battery-powered data logger with integrated CO2 and atmospheric pressure sensor and 4 universal inputs for measuring temperature, humidity, voltage 0-10 V, current 0-20 mA, bi-state signal and for counting pulses.The Multilogger can be permanently installed on an Ethernet...
More
In stock

Follow us on Facebook