Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock
All best sellers
  • PAYMENT METHODS

M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals
  • M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals

M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals

M1323

M1323 Multilogger - thermo-hygro-CO2-barometer with 2 MiniDIN and 2 Terminals

Battery-powered data logger with integrated CO2 and atmospheric pressure sensor and 4 universal inputs for measuring temperature, humidity, voltage 0-10 V, current 0-20 mA, bi-state signal and for counting pulses.
The Multilogger can be permanently installed on an Ethernet network or operated as a handheld device.
A traceable calibration certificate according to EN ISO/IEC17025 is included.

The Multilogger is a battery-powered data logger that can measure and record electrical and sensor values ​​via its inputs.

The data logger can be connected to Ethernet. The measured values ​​can then be viewed in a web browser as well as stored and downloaded for further analysis.

Carbon dioxide

Measuring range can be extended for an additional charge:

Measuring range: 0 to 10,000 ppm
Accuracy: 100 ppm + 5% of measured value at 25 °C and 1013 hPa

Quantity

Description

Technical data

Measured value
Temperature
Relative humidity
Counted values (dew point…)
CO2
Atmospheric pressure
Current
Voltage
Two-state signal
Pulses

TEMPERATURE SENSOR - external probe Pt1000

Measuring range -200 to +600 °C
Accuracy ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C
Resolution 0.1 °C

TEMPERATURE+HUMIDITY SENSOR - external probe T+RH DIGI

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C

DEW POINT

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C

ATMOSPHERIC PRESSURE SENSOR

Measuring range 700 hPa to 1100 hPa
Accuracy ±1,3 hPa at 23 °C
Resolution 0.1 hPa

CO2 SENSOR
Measuring range 0 to 2 000 ppm
Accuracy 50 ppm + 2 % of the measured value at 23 °C a 1013 hPa
Resolution 1 ppm

DC VOLTAGE

Measuring range 0 to 10 V
Accuracy ±10 mV
Resolution better than 100 µV

DC CURRENT

Measuring range 0 to 20 mA
Accuracy ±20 µA
Resolution better than 0.1 µA

BINARY SIGNAL

Input voltage for “on” level / <0.4 V/> 2 V
Minimum/maximum input voltage 0 V/+30 V DC
“On” impedance / <10 kOhm/> 300 kOhm

COUNTER INPUT

Counter range 24 bit (16 777 215) counter overflow allowed
Maximum input frequency 200 Hz

GENERAL TECHNICAL DATA

  • Operating temperature: -10 to +60 °C
  • Channels internal atmospheric pressure sensor to CO2, 2x external temperature probe or temperature+humidity probe connectable, 2x binary input, counter, voltage and current
  • Counted values ​: dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Memory: 1 000 000 values ​​(non-cyclic logging), 600 000 values ​​(cyclic logging)
  • Logging interval: 1 s to 24 hours
  • Display and alarm update every: 10 s
  • Logging mode non-cyclic: data logging stops after memory is full cyclic: after memory is full, oldest data is overwritten with new data
  • Available temperature units: degrees Celsius, degrees Fahrenheit
  • Communication interface: Ethernet, USB, RS232
  • Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
  • Alarm protocols: Email
  • Power: AC adapter 230 V AC/5 V DC (required for Ethernet interface)
  • Battery life :3 - 4 weeks
  • Protection class: IP20
  • Dimensions (without connectors): 178 x 95 x 37 mm, without connected cables
  • Weight (including batteries): approx. 380g
  • Warranty: 3 years

Features

Up to 4 physical inputs - 2x TERMINALS + 2x MiniDin



Sensors with voltage output (range 0-10 V; accuracy ±10 mV)
Sensors with current output (range 0-20 mA; accuracy ±20 µA)
Devices with dual-state output (potential-free contact or 0-30 V voltage signal); can be applied to input 3 and 4
Devices with pulse signal (potential-free contact or 0-30 V voltage signal); can be applied to input 4
Pt1000 temperature probes with built-in configuration memory (xxx/M series)
Temperature/relative humidity probes with digital output - DigiS/M, DigiL/M, DIGIH/M
Probes are interchangeable without calibration to a specific device and regardless of cable length. Cable length can be 1, 2, 5, 10, 15 meters
Internal CO2 sensor with range 0 to 2000 ppm (custom range 0 to 10,000 ppm)
Internal barometric pressure sensor (range 600 to 1100 hPa; accuracy ±1.3 hPa at 23 °C)




Evaluation of up to 16 variables


Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be an additional expression of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can also be the result of conversions between channels, e.g. the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The recording mode can be set as non-cyclic, when recording stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

The measured values ​​are displayed on the display with backlight option and the ability to change the size of the display digits.




Power supply



Multilogger can be operated from an AC adapter or from rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and enable recording and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.






Alarm limits and alarm indication


It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signalling can be acoustic (built-in buzzer), optical, by sending an alert by email or an alarm output. The alarm output is for connecting an external visual or audio alarm.





Communication interfaces

Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.
Multilogger - Alarm limits

sends an email when an alarm state begins or ends
uses DATALINK: displays current values ​​or downloads values ​​from memory to the COMET database on your PC. The COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
Simple wireless communication with TP-LINK Wi-Fi router
Third-party apps to read actual measured values ​​using universal SNMPv1 and XML protocols
View current measured values ​​using your web browser





ALARM OUT output


The output can be used to control other devices when the alarm is triggered, such as an external buzzer, telephone dialer, etc.
Output type: Open collector transistor
Maximum switching current: 100 mA
Maximum switching current: 100 mA Output voltage: 24 V
Auxiliary voltage at terminal: +5 V (only when mains power is present)
Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated by an internal buzzer, 3 LEDs, or email alerts via the Ethernet port.

Product Details
M1323
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: UTAI

Brand:

UTAI indoor thermohygrometric sensor

(0)
Sensor for measuring temperature and humidity of air in indoor environments. Compact and robust, it can be interconnected with a wireless transmission module using the ZigBee protocol in such a way as to allow the creation of a network composed of multiple sensors, which can be acquired directly by a Nesa TMF100 or TMF500 series data logger using a...
More
In stock

Reference: SR05-D1A3

Brand: Hukseflux

SR05-D1A3 Pyranometer

(0)
Digital second class pyranometer with Modbus RS-485 and 0-1 V output SR05 series is the most affordable range of pyranometers meeting ISO 9060 second class requirements. SR05 measures solar radiation received by a plane surface, in W/m², from a 180 ° field of view angle. It is ideal for general solar radiation measurements in (agro-)meteorological...
Price €645.00
More
In stock

Reference: 67130012

Brand: FUEL CELL

Flex-Stak Electrochemical Cell

(0)
Flex-Stak Electrochemical Cell The Flex-Stak is a detachable electrochemical stack that allows users to insert their own custom PEM MEAs for testing. Independent reagent flow on each side of the MEA allows this setup to be used in many different configurations.
More
In stock

Reference: SR15-A1

Brand: Hukseflux

SR15-A1 Piranómetro

(0)
Analogue first class pyranometer with heater SR15-A1 is a high-accuracy solar radiation sensor. It is "First Class" according to the ISO 9060:1990 standard and “Spectrally Flat Class B” in the 2018 revision. With its on-board heater, it is compliant in its standard configuration with the requirements for “Class B” PV monitoring systems of the new IEC...
More
In stock

Reference: HFP01SC

Brand: Hukseflux

HFP01SC Heat Flux Sensor

(0)
Self-calibrating heat flux sensor HFP01SC self-calibrating heat flux sensor™ is a heat flux sensor for use in the soil. It offers the best available accuracy and quality assurance of the measurement. The on-line self-test verifies the stable performance and good thermal contact of sensors that are buried and cannot be visually inspected and taken to the...
More
In stock

Reference: SR05-D2A2

Brand: Hukseflux

SR05-D2A2 Pyranometer

(0)
Digital second class pyranometer with Modbus over TTL and 4-20 mA output SR05 series is the most affordable range of pyranometers meeting ISO 9060 second class requirements. SR05 measures solar radiation received by a plane surface, in W/m², from a 180 ° field of view angle. It is ideal for general solar radiation measurements in (agro-)meteorological...
Price €645.00
More
In stock

Reference: RXW-THC-868

Brand: ONSET

RXW-THC-868 HOBOnet Temp/RH Sensor

(0)
Important InformationA complete system requires at least one HOBO RX3000 Remote Monitoring Station, a HOBOnet Wireless Manager, and a HOBOnet Wireless Sensor, OR one HOBO MicroRX Station (which has an integrated HOBOnet Wireless Manager) and a HOBOnet Wireless Sensor. HOBOnet Wireless Repeaters (RXW-RPTR-xxx or RXW-RPTR-B-xxx) can be added to extend the...
Price €300.00
More
In stock

Reference: M1140

Brand: COMET

M1140 Ethernet Multilogger - thermo hygro meter with 4 MiniDIN inputs

(0)
M1140 Ethernet Multilogger - thermo hygro meter with 4 MiniDIN inputs Universal datalogger with MiniDIN inputs for connecting up to four temperature and/or humidity probes.Multilogger can be installed permanently to Ethernet network or work as portable device.Included is traceable calibration certificate in accordance with EN ISO/IEC17025.The Multilogger...
More
In stock

Follow us on Facebook