UG-5-AFR-24V Smoke Detector for Air Ventilation Ducts
VdS, CE, DIBt
Built-in control unit (stand alone)
2 alarm relays, 1 service alarm, 1 system error relay, 1 low-flow relay, Modbus
Quick and simple installation
Flow indicator with high sensitivity
4 install positions 0, 90, 180 and 270°
Test hole in cover
ST2 - Venturi pipe for duct smoke detector
Description: Venturi pipe for duct smoke detector UG-5, 0,6 m Weight: 340 g
The UG-5 duct smoke detector has been developed to detect smoke in ventilation ducts and combines a smoke detector and an adaptor system where both tube and housing are specially designed for optimum airflow through the smoke detector. The detector can be installed on any side of the duct in four different positions: 0°, 90°, 180° and 270°. The smoke detector has 2 alarm relays to control fire-safety dampers, to stop ventilation fans or to activate acoustic and optical alarms etc., 1 service alarm relay to let you know when maintenance is needed, before a false alarm occurs, 1 system error relay indicating fault on the smoke detector circuit, 1 low-flow relay indicating that air flow in the duct is low or that the UG-5 is installed in an inexpedient place on the duct. The smoke detector contains an intelligent controlling circuit. This circuit is adjusting the sensitivity to give an optimal function during the whole life time of the detector. When the controlling circuit has reached the maximum sensitivity compensation for contamination, a service alarm is indicated. The detector has a bayonet fitting to simplify mounting and removal.
TECHNICAL DATA | |
Measuring principle: | opto-electronic |
Supply voltage: | 24 V AC/DC or 230 V AC (±10%) |
Current consumption: | max. 30 mA at 230 V AC, max. 220 mA at 24 V AC/DC |
Alarm output: | 2 x potential-free change-over contact max. 250 V (8 A), 3 x potential-free normally-open contact max. 250 V (8 A) |
Equipment: | LED on smoke detector: green - service alarm, red - smoke alarm; LED on PCB: green - normal operation, yellow - system error, yellow - low-flow, red - smoke alarm (only in version '-Z'), red blinking - alarm memory (only in version '-Z') |
Housing: | ABS Synthetic |
Protection type: | IP54 |
Protection class: | II |
Working range r.H.: | 0...99% r.H. |
Working temperature: | -10...+55°C |
Approvals: | VdS G205041, CE, prEN-54-27, DIBt Z-78.6-232CE-conformity, prEN-54-27, DIBt Z-78.6-232 (abhängig von Variante). |
Dimensions: | venturi pipe: opening diameter 38 mm ((available as an accessory in lengths of 0.6m (ST2), 1.5m (ST5) or 2.8m (ST9)) |
Flow rate: | 1-20 m/s |
Weight: | ca. 1100 g |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: BHW-PRO
Brand: ONSET
Reference: RK300-04
Brand: RIKA SENSORS
Reference: HFP03
Brand: Hukseflux
Reference: DTSAA
Brand: RST
Reference: SPD01
Brand: Hukseflux
Reference: 12120008
Brand: FUEL CELL
Reference: LS155
Brand: LINSHANG
Reference: ZL6 BASIC
Brand: METER GROUP
Reference: 11060044 -5x5
Brand: FUEL CELL
Reference: TR43A
Brand: TandD
Reference: TCOMSYS01
Brand: Hukseflux
Reference: RK220-01
Brand: RIKA SENSORS
Reference: EQMP
Brand: Meatrol
UG-5-AFR-24V Smoke Detector for Air Ventilation Ducts
VdS, CE, DIBt
Built-in control unit (stand alone)
2 alarm relays, 1 service alarm, 1 system error relay, 1 low-flow relay, Modbus
Quick and simple installation
Flow indicator with high sensitivity
4 install positions 0, 90, 180 and 270°
Test hole in cover
ST2 - Venturi pipe for duct smoke detector
Description: Venturi pipe for duct smoke detector UG-5, 0,6 m Weight: 340 g