Industrial Class B pyranometer
Hukseflux introduces “industrial grade” solar radiation monitoring. The fully digital Class B pyranometer model SR100-D1 is designed to measure solar radiation with maximum reliability and measurement accuracy.
• designed for Class B PV system performance monitoring according to IEC 61724-1
• built-in surge protection, designed to withstand the extreme conditions found in PV power plants, upgradeable to 4 kV with the optional SPD01 surge protection device
• RS-485 isolation – galvanic isolation, for reliable operation and flexibility in system design
• complies with IEC 61326-1 “Industrial Equipment” – rated for industrial electromagnetic environments
• enables system designers to comply with local safety regulations
• designed to minimize integration costs
• supported by a worldwide calibration organization for the lowest total cost of ownership
Measurand: | hemispherical solar radiation |
ISO 9060:2018 classification: | spectrally flat Class B pyranometer |
IEC 61724-1:2021 compliance: | meets Class B PV monitoring system requirements |
Dome protector: | included (model DP01) |
Instrument diagnostics: | internal humidity |
Calibration certificate: | included (content limited according to ISO/IEC 17025, section 7.8.1.3) |
Standard cable length (not included) : | 3 m |
EMC and Surge immunity * : | : |
Equipment classification: | Industrial Equipment |
Surge Immunity: | Level 2, test level 1 kV |
with optional SPD01: | Level 4, test level 4 kV |
Electrical Safety in the workplace | : |
Safety compliance: | EU Low Voltage Directive (2014/35/EU) / USA National Electric Code (NFPA70) |
Earthing terminal: | included on instrument |
Digital communication: | : |
Communication protocol: | Modbus RTU |
RS-485 isolation voltage: | 1.5 kV |
Hardware interface: | 2-wire RS-485 |
* | at standard cable length of 3 m |
** | 24 VDC |
Options
We offer accessories for use with the SR100-D1, including electrical and mounting hardware options.
• SPD01 Surge Protection Device (for 1 to 3 instruments) for cables longer than 3 meters and to upgrade surge protection to Level 4
• PID01 Pyranometer Isolation Disk, which electrically isolates the instrument from the mounting platform, spring-loaded for easy leveling
• LM01 Spring-loaded Leveling Stand; a handy stand for easy mounting, leveling, and exchanging instruments on flat surfaces
• TLM01 Pipe Leveling Stand with a set of bolts
• Calibration Certificate including customer name and contact information
• DP01 Dome Guard, 5-piece set
• AMF03 Albedometer Attachment
• PMF01 and PFM02 Mounting A
SR100-D1: affordable industrial-grade pyranometer
SR100-D1 may look like its predecessor, but in many ways it is a completely new instrument. We built upon the measurement capabilities of the earlier pyranometer model SR15-D1 and tailored the SR100-D1 pyranometer to its most common applications in PV system performance monitoring systems and meteorological stations.
SR100-D1 complies with – Industrial-grade – Immunity, Emission, Electrical, Environmental and Safety requirements for use in these outdoor and industrial environments, greatly improving measurement reliability. Ease of operation is further enhanced through extended functionality and diagnostics.
PV System performance monitoring: IEC 61724-1 Class B complian
SR100-D1 complies with IEC requirements for “Class B” PV system performance monitoring. If you need a pyranometer that complies with all locations and climatic conditions, consider the SR300-D1 pyranometer.
Immunity to high voltages and currents -surges
SR100-D1 is tested and classified for Industrial Environments according to IEC 61326-1 and IEC 61000-6-2. When designing a measuring system, pyranometer users may reach several levels of immunity.
With the optional Surge Protection Device SPD01 this immunity can be increased to 4 kV. Up to 3 pyranometers can be protected with a single SPD01. A third-party SPD with similar specifications may be used instead.
To attain the required level of immunity for a given installation, some general system components should be included, such as:
• lightning protection system
• earthing and grounding network
• external surge protection in addition to the native on-board sensor protection
RS-485 isolation
The RS-485 interface of the industrial pyranometers is galvanically isolated from the internal electronics as well as from the instrument body. Both isolation barriers are rated at 1.5 kV. This contributes to reliable operation, flexibility in system design and reduced integration costs for all industrial pyranometers.
Electrical safety in the workplace
A PV power plant is a potentially hazardous workplace environment. To comply with safety regulations, SR100-D1 features a dedicated earthing terminal for connection to protective earth. When the pyranometer is isolated from the mounting platform, it should still be properly earthed via this terminal. SR100-D1 allows system designers to comply with safety regulations. These are often based on EU and US electrical safety standards such as:
• EN-50110 Operation of Electrical Installations
• NFPA 70 National Electrical Code (NEC)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: M2 T
Brand: tempmate
Reference: AT-100 microCACHE
Brand: Apogee Instruments
Reference: RTR500BW
Brand: TandD
Reference: RL2/A-UI
Brand: FUEHLER SYSTEME
Reference: 570802511gr
Brand: FUEL CELL
Reference: BH-H3
Brand: BOSEAN
Reference: SBG01
Brand: Hukseflux
Reference: UX120-006M
Brand: ONSET
Reference: WLB0002M
Brand: RST
Reference: RK300-04
Brand: RIKA SENSORS
Reference: V5A
Brand: FRIGGA
Reference: LS197
Brand: LINSHANG
Reference: SQ-100X-SS
Brand: Apogee Instruments
Reference: ZRC-50
Brand: Meatrol
check_circle
check_circle