U7844M IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem
GSM datalogger is designed to record from four binary inputs or from two pulse and two binary inputs. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.
It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.
GSM datalogger inputs can be set up for four binary inputs or two binary inputs and two pulse counters.
The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Technical data
Measured value
Two-state signal
Pulses
BINARY INPUT
Parameters of the voltage contact „L“ level input voltage:< 0,4 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 300 kOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s
COUNTER INPUT
Counter parameters Range 24 bits (16 777 215), possibility of letting the counter overflow
Maximum pulse frequency configured for voltage input - max. 5kHz
configured for a voltage-free or open-collector transistor - max. 200Hz
GSM MODEM PARAMETERS
Quad-band 850/900/1800/1900MHz
Compliant to GSM Phase2/2+
GPRS GPRS mobile station class B
Class 4 2W @ 850/900MHz
Class 1 1W @ 1800/1900MHz
GENERAL TECHNICAL DATA
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: LM 510-H/UVIS
Brand: Photon System Instruments (PSI)
Reference: T-Z03
Brand: BOSEAN
Reference: U30-NRC-SYS-C
Brand: ONSET
Reference: 12120041
Brand: FUEL CELL
Reference: GT-K90
Brand: BOSEAN
Reference: U5841G
Brand: COMET
Reference: RK400-04
Brand: RIKA SENSORS
Reference: RK330-01B
Brand: RIKA SENSORS
Reference: DS1402D-DR8+
Brand: iBUTTON MAXIM INTEGRATED
Reference: RK310-01 PT100 / PT1000
Brand: RIKA SENSORS
Reference: U0141
Brand: COMET
Reference: 11044001
Brand: FUEL CELL
Reference: PX3UXX05S
Brand: VERIS
Reference: 42010
Brand: Innoquest, Inc.
Reference: KIT-D-U20-01
Brand: ONSET
Reference: H721HC
Brand: VERIS
U7844M IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem
GSM datalogger is designed to record from four binary inputs or from two pulse and two binary inputs. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.
It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.
GSM datalogger inputs can be set up for four binary inputs or two binary inputs and two pulse counters.
The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
check_circle
check_circle