Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock

Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock
All best sellers
  • PAYMENT METHODS

M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port

M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port

M1200

Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

 

Quantity

Description

Technical data

Measured value

Temperature

TEMPERATURE SENSOR - thermocouple K, N
Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple S

Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple B

Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple T

Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

DC VOLTAGE

Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV

GENERAL TECHNICAL DATA

  • Operating temperature: -10 to +60 °C
  • Channels: 4x external temperature probe
  • Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
  • Recording interval: 1s to 24 hours
  • Display and alarm refresh: each 10 s
  • Recording mode: noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
  • Available temperature units: degrees Celsius, degrees Fahrenheit
  • Communication interface: Ethernet, USB, RS232
  • Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
  • Alarm protocols: E-Mail
  • Power AC adapter: 230Vac/5Vdc (neccessary for Ethernet interface)
  • Battery life: 3 - 4 weeks
  • Protection class: IP20
  • Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
  • Weight (including batteries) approx.: 380 g
  • Warranty: 3 years

Features

Up to 4 physical thermocouple inputs


  • Thermocouple probe K, J, S, B, T, N
  • Direct input of bipolar voltages with a range of up to -60 to +140 mV
  • Sensors with voltage output (range -60 to +140 mV; accuracy ±100 µV or -18 to +18 mV; accuracy ±20 µV)






Evaluation of up to 16 variables



Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be the result of conversions between channels, e.g. the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The logging mode can be set as non-cyclic, when logging stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

The measured values ​​are displayed on the display with backlight option and the ability to change the size of the display digits.





Power


Multilogger can be powered by an AC adapter or by rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and provide logging and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.









Alarm limits and alarm indication


It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signaling can be acoustic (built-in buzzer), optical, sending an alert via email or an alarm output. The alarm output is for connecting an external visual or audio alarm.







Communication interfaces
Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.





sends an email when an alarm state begins or ends
uses DATALINK: displays current values ​​or downloads values ​​from memory to the COMET database on your PC. The COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
Simple wireless communication with TP-LINK Wi-Fi router
Third-party apps to read actual measured values ​​using universal SNMPv1 and XML protocols
View current measured values ​​using your web browser







ALARM OUT output

  • The output can be used to control other devices when the alarm is triggered, such as an external buzzer, telephone dialer, etc.
  • Output type: Open collector transistor
  • Maximum switching current: 100 mA
  • Maximum switching current: 100 mA Output voltage: 24 V
  • Auxiliary voltage at terminal: +5 V (only when mains power is present)
  • Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated by an internal buzzer, 3 LEDs, or email alerts via the Ethernet port.





Product Details
M1200
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: U0110M

Brand: COMET

U0110M IoT Wireless Temperature Datalogger with built-in sensor and 2G modem

(0)
U0110M IoT Wireless Temperature Datalogger with built-in sensor and 2G modem GSM datalogger is designed to record temperature. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.It is also...
More
In stock

Reference: 7714

Brand: DAVIS INSTRUMENTS

7714 Radiation Shield

(0)
7714 Radiation Shield A temperature probe exposed to direct sunlight or a radiant heat source, such as a building or concrete, will not provide accurate air temperature readings. This radiation shield is the most effective passive shield available. Multi-plate construction for maximum airflow. Assembly required. Can be mounted on a metal pipe or wooden...
Price €135.00
More
In stock

Reference: SU-220

Brand: Apogee Instruments

SU-220: USB output UV-A Sensor

(0)
SU-220: USB output UV-A Sensor The SU-220 UV-A, smart sensor can be connected directly to a computer (Windows or macOS X) via USB for taking spot measurements or graphing and datalogging real-time PPFD using the included software.
Price €625.00
More
In stock

Reference: DS1921K

DS1921K Thermochron iButton Starter Kit

(0)
DS1921K Thermochron iButton Starter Kit The DS1921K Thermochron iButton® Starter Kit provides basic hardware for a quick evaluation of Dallas Semiconductor's Thermochron iButton. The kit includes a Thermochron iButton and the hardware to communicate with it.
More
In stock

Reference: SpectraPen SP 110

Brand: Photon System Instruments (PSI)

SpectraPen SP 110 portable spectrophotometer

(0)
SpectraPen SP 110 portable spectrophotometer The SpectraPen SP 110 is a low-cost, handheld spectrophotometer that is ideal as a general-purpose instrument for research labs, agricultural and industrial applications.SpectraPen is especially useful for rapid measurements of solar irradiance and monitoring of spectral light quality. External light source and...
From Price €3,845.00
More
In stock

Reference: INTEGRADOR S10 MINI

Brand: Meatrol

INTEGRADOR S10 MINI

(0)
The S10 is a mini Rogowski coil integrator combined with power meter or PLC, in a plastic case, powered directly from the main one.
More
In stock

Follow us on Facebook