Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
All best sellers
  • PAYMENT METHODS

  • New
M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port
  • M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port

M1200 Multilogger - Thermometer with 4 Thermocouple Inputs and Ethernet port

M1200

Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

 

Description

Technical data

Measured value

Temperature

TEMPERATURE SENSOR - thermocouple K, N
Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple S

Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple B

Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple T

Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

DC VOLTAGE

Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV

GENERAL TECHNICAL DATA

  • Operating temperature: -10 to +60 °C
  • Channels: 4x external temperature probe
  • Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
  • Recording interval: 1s to 24 hours
  • Display and alarm refresh: each 10 s
  • Recording mode: noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
  • Available temperature units: degrees Celsius, degrees Fahrenheit
  • Communication interface: Ethernet, USB, RS232
  • Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
  • Alarm protocols: E-Mail
  • Power AC adapter: 230Vac/5Vdc (neccessary for Ethernet interface)
  • Battery life: 3 - 4 weeks
  • Protection class: IP20
  • Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
  • Weight (including batteries) approx.: 380 g
  • Warranty: 3 years

Features

Up to 4 physical thermocouple inputs


  • Thermocouple probe K, J, S, B, T, N
  • Direct input of bipolar voltages with a range of up to -60 to +140 mV
  • Sensors with voltage output (range -60 to +140 mV; accuracy ±100 µV or -18 to +18 mV; accuracy ±20 µV)






Evaluation of up to 16 variables



Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be the result of conversions between channels, e.g. the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The logging mode can be set as non-cyclic, when logging stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

The measured values ​​are displayed on the display with backlight option and the ability to change the size of the display digits.





Power


Multilogger can be powered by an AC adapter or by rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and provide logging and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.









Alarm limits and alarm indication


It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signaling can be acoustic (built-in buzzer), optical, sending an alert via email or an alarm output. The alarm output is for connecting an external visual or audio alarm.







Communication interfaces
Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.





sends an email when an alarm state begins or ends
uses DATALINK: displays current values ​​or downloads values ​​from memory to the COMET database on your PC. The COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
Simple wireless communication with TP-LINK Wi-Fi router
Third-party apps to read actual measured values ​​using universal SNMPv1 and XML protocols
View current measured values ​​using your web browser







ALARM OUT output

  • The output can be used to control other devices when the alarm is triggered, such as an external buzzer, telephone dialer, etc.
  • Output type: Open collector transistor
  • Maximum switching current: 100 mA
  • Maximum switching current: 100 mA Output voltage: 24 V
  • Auxiliary voltage at terminal: +5 V (only when mains power is present)
  • Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated by an internal buzzer, 3 LEDs, or email alerts via the Ethernet port.





Product Details
M1200
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: HF03-LI19

Brand: Hukseflux

HF03-LI19 - HEAT FLUX SENSOR

(0)
Portable heat flux sensor, with read-out unit / datalogger HF03 is a heat flux sensor that is applied in mobile measurements. It is combined with LI19, a high accuracy handheld read-out unit / datalogger. The combination HF03- LI19 is typically used to study heat flux levels of flares and fires, and to verify the performance of permanently installed flare...

Reference: H21-USB

Brand: ONSET

H21-USB - HOBO USB Microstation Data Logger

(0)
Features Compact size for easy deployment Weatherproof IP66 enclosure for harsh environments Direct USB offload--no need for an adapter cable Includes five Smart Sensor inputs Hinged door and integrated mounting tabs Runs for up to a year on four standard AA batteries Compatible with HOBOware and HOBOware Pro software for logger setup and graphing &...

Reference: DV-DENDRO

Brand: ECOMATIK

DV- Vertical Dendromete

(0)
DV- Vertical Dendromete The DV dendrometer is used for high-precision and continuous measurement of vertical changes in dimension and/or curvature of tree stems. This device is suitable for long-term in outdoor conditions. Due to their extremely low power consumption, Ecomatik dendrometers are ideal for battery-powered solutions, e.g., in IoT applications.

Reference: S-100

Brand: BOSEAN

S-100 Gas Leak Detector

(0)
The S-100 portable gas leak detector adopts advanced integrated circuit technology and standard intelligent technology. The detector adopts a natural diffusion type for gas sampling and high-quality gas sensors for gas detection, which have good sensitivity and excellent repeatability. It is easy to use and maintain,greatly meeting the high reliability...

Reference: PL200

Brand: NESA

PL200 200 cm² Class A Rain Gauge

(0)
El pluviómetro Helmmann PL200 es un pluviómetro manual formado por un cuerpo cilíndrico de aluminio anodizado con una superficie de recogida de 200 cm² que recoge la lluvia en un recipiente de hasta 3 litros de capacidad (que corresponde a 150 mm) o directamente en un recipiente de clase A o A+ de 250 ml (250 cm3) equivalente a 12,5 mm de precipitación...

Reference: LAQUAtwin Salt-22

Brand: HORIBA LAQUAtwin

Salt-22 LAQUAtwin Pocket Water Quality Meter

(0)
Salt-22 LAQUAtwin Pocket Water Quality Meter The only pocket meter that directly measures the sodium ion concentration in a 0.3 mL sample (or 0.05 mL with Sampling Sheet B) and converts it to salinity or NaCl salt concentration. No beaker is needed to calibrate the meter or measure a sample. Simply place a few drops of the standard or sample on the...

Follow us on Facebook