Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: VH400-2M
Brand: VEGETRONIX
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
Technical data
Measured value
Temperature
TEMPERATURE SENSOR - thermocouple K, N
Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple S
Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple B
Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple T
Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
DC VOLTAGE
Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV
GENERAL TECHNICAL DATA
Features
Up to 4 physical thermocouple inputs
Evaluation of up to 16 variables
Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values can be the result of conversions between channels, e.g. the difference of two connected temperature probes.
The measured values are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The logging mode can be set as non-cyclic, when logging stops after filling the memory, or cyclic, when after filling the memory the oldest stored values are overwritten with the new ones.
The measured values are displayed on the display with backlight option and the ability to change the size of the display digits.
Power
Multilogger can be powered by an AC adapter or by rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.
While using the AC adapter, the batteries provide backup operations and provide logging and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.
Alarm limits and alarm indication
It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).
Alarm signaling can be acoustic (built-in buzzer), optical, sending an alert via email or an alarm output. The alarm output is for connecting an external visual or audio alarm.
Communication interfaces
Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.
sends an email when an alarm state begins or ends
uses DATALINK: displays current values or downloads values from memory to the COMET database on your PC. The COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
Simple wireless communication with TP-LINK Wi-Fi router
Third-party apps to read actual measured values using universal SNMPv1 and XML protocols
View current measured values using your web browser
ALARM OUT output
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: RK500-23
Brand: RIKA SENSORS
Reference: MQ31
Brand: Meatrol
Reference: S635-LUX-UV
Brand: HUATO
Reference: 28010001
Brand: FUEL CELL
Reference: MX2501
Brand: ONSET
Reference: FS6003-MBR-A1B1H1R1T1W1W2-G
Brand: FUEHLER SYSTEME
Reference: ELSGT610
Brand: RST
Reference: SP-230-SS
Brand: Apogee Instruments
Reference: 41430
Brand: Innoquest, Inc.
Reference: SFL
Reference: SQ-204X-SS
Brand: Apogee Instruments
Reference: VW0420
Brand: RST
Reference: S-WCG-M003
Brand: ONSET
Reference: RTR-602ES
Brand: TandD
Reference: RK100-01
Brand: RIKA SENSORS
Reference: U3121M
Brand: COMET
Universal datalogger with 4 inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
check_circle