Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS9107+
Brand: iBUTTON MAXIM INTEGRATED
ORP-11 LAQUATWIN ORP (OXIDATION-REDUCTION POTENTIAL) meter
It is a REDOX POTENTIAL (ORP) meter used in a wide variety of analyses and measurements. It measures ORP reliably and is very easy to use. It takes only a few seconds to give a result, making it an ideal instrument for field analysis.
Freshwater analysis.
- Aquariums.
- Wastewater.
- Soil analysis for improved agriculture.
- Disinfectants.
- Fermentation and brewing.
- Research laboratories.
- Quality control of medical and cosmetic products.
- Preventive dentistry.
- School education.
These devices incorporate a platinum flat ion electrode for microvolume measurement. Only a few drops (0.3 ml) are required to provide a fast and accurate analysis.
It can be used as a traditional ORP meter by immersing the electrode in a liquid.
Main features:
Temperature compensation.
Automatic calibration: recognizes the calibration solution.
Detection of the stability of the result.
Waterproof (IP67).
Automatic selection of the appropriate range.
Automatic shutdown (30 minutes).
Different methods for measurement:
Immersion: You can analyze the sample in a beaker.
Sampling: Use it as a shovel to analyze the water.
Drops: LAQUAtwin meters can measure sample volumes as small as 0.05 ml by placing a drop of the sample onto the sensor using a pipette.
Solid samples: Foods containing some moisture can be analysed by placing a small piece directly onto the sensor.
Powders: Simply place the powder sample onto the sensor and pour the defined volume of deionised water over it.
Paper and textiles: If you wish to analyse sheets of paper and textiles, cut the sample into small pieces and place them directly onto the sensor. Pour the defined volume of deionised water over them.
Measurement in three easy steps:
. Calibration: For a correct calibration, the sensor must be clean beforehand. If not, rinse it with water and place a little standard solution on the sensor and press the calibration button. A smiley face will appear indicating that the calibration is complete. Clean the sensor with water until the calibration solution is removed and dry it with a soft, clean tissue.
. Analysis: Only a tiny amount of sample is needed, so just fill the sensor and wait a few seconds until the smiley face appears.
. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1500 measurements or when calibration cannot be performed. Sensors are sold separately and can be easily removed and replaced.
The ORP-11 meter is supplied with:
2CR2032 batteries
1 pipette.
Instruction manual and Quick Start Guide.
Storage case.
225 mV calibration solution (14 ml).
Abrasive cotton swab.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: U23-002A
Brand: ONSET
Reference: RTR503B
Brand: TandD
Reference: PX3UXN05S
Brand: VERIS
Reference: TR-74Ui-S
Brand: TandD
Reference: 11060044 -5x5
Brand: FUEL CELL
Reference: LM 510-H/UVIS
Brand: Photon System Instruments (PSI)
Reference: TA Sensor de temperatura
Reference: K-600
Brand: BOSEAN
Reference: KIT-D-U20-02
Brand: ONSET
Reference: SF-HP
Brand: ECOMATIK
Reference: M1200E
Brand: COMET
Reference: TCR24
Brand: MAE
Reference: FS4408-UI-A51-X
Brand: FUEHLER SYSTEME
Reference: K-600
Brand: BOSEAN
Reference: PX3ULX05
Brand: VERIS
Reference: H721LC
Brand: VERIS
check_circle
check_circle