- New
Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS9107+
Brand: iBUTTON MAXIM INTEGRATED
M1200E Multilogger - Low Cost Thermometer with 4 Thermocouple Inputs
M1200E is a battery operated datalogger that allows to monitor the actual measured values on the device display or to work with historical data in Comet Vision, where you can create table charts, PDF export, MS EXCEL.
The device is designed for measuring and recording with 4 inputs for thermocouples K, J, S, B, T, N.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
M1200E is a battery operated datalogger that allows to monitor the actual measured values on the device display or to work with historical data in COMET Vision, where you can create table charts, PDF export, MS EXCEL. The device is designed for measuring and recording with 4 inputs for thermocouples K, J, S, B, T, N. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
Technical data
Measured value
Temperature
TEMPERATURE SENSOR - thermocouple K, N
Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple S
Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple B
Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple T
Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
DC VOLTAGE
Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV
GENERAL TECHNICAL DATA
Operating temperature: -10 to +60 °C
Channels: 4x external temperature probe
Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
Recording interval: 1s to 24 hours
Display and alarm refresh each: 10 s
Recording mode noncyclic: - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
Available temperature units: degrees Celsius, degrees Fahrenheit
Communication interface: USB
Power: 3x AA alkaline battery 1.5 V
Battery life: 3 - 4 weeks
Protection class: IP20
Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
Weight (including batteries) approx.: 380 g
Warranty: 3 years
Features
Up to 4 physical thermocouple inputs
Thermocouple probe K, J, S, B, T, N
Direct input of bipolar voltages with range up to -60 to +140 mV
Sensors with voltage output (range -60 to +140 mV; accuracy ±100 µV or -18 to +18 mV; accuracy ±20 µV)
Evaluation of up to 16 variables
Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values can be the result of conversions between channels, e.g. the difference of two connected temperature probes. Detail of the Multilogger LCD display.
The measured values are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The logging mode can be set as non-cyclic, when logging stops after filling the memory, or cyclic, when after filling the memory the oldest stored values are overwritten with the new ones.
Measured values are displayed on the display with backlight option and the ability to change the size of the display digits.
Power supply
Multilogger can be operated from an AC adapter or from rechargeable batteries with charging capacity. Batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.
While using the AC adapter, the batteries provide backup operations and allow logging and measurement during a power outage.
Alarm limits and alarm indication
It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).
Alarm signaling can be acoustic (integrated acoustic warning), visual (LED, LCD)
Communication interfaces
The Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: U0121M
Reference: U6841G I
Brand: COMET
Reference: U-DTW-1
Brand: ONSET
Reference: Chione
Brand: NESA
Reference: DV-DENDRO
Brand: ECOMATIK
Reference: U30-NRC-SYS-C
Brand: ONSET
Reference: ACCUPAR LP-80
Reference: DC1
Brand: ECOMATIK
Reference: RTR503BL
Brand: TandD
Reference: DLI-500
Brand: Apogee Instruments
Reference: K-10
Brand: BOSEAN
Reference: S030
Brand: HORIBA LAQUAtwin
Reference: 514‐50
Brand: HORIBA LAQUAtwin
Reference: RTR500BC
Brand: TandD
Reference: TR43A
Brand: TandD
check_circle