LAQUAtwin F‐11 Fluoride Ionometer
It is a fluoride meter used in a wide variety of analyses and measurements. It measures fluoride reliably and is very easy to use. It takes only a few seconds to give a result, making it an ideal instrument for field analysis.
Especificaciones:
The wide measuring range (0.1 to 990 ppm) allows high concentrations to be measured without the need for dilution.
Uses:
- Evaluation of fluoride concentration in water.
- Analysis of sap.
- Analysis of oral hygiene products.
- Different uses in laboratories and universities.
These devices incorporate a flat ion electrode for microvolume measurement. The replaceable electrode uses the same measuring principle as the traditional fluoride ion selective electrode (ISE). They only require a few drops (0.3 ml) to provide a fast and accurate analysis.
It can be used as a traditional fluoride meter by immersing the electrode in a liquid.
An absorbent paper allows us to analyze microsamples from 100 µl.
Main features:
Temperature compensation.
Automatic calibration: recognizes calibration solutions. The user can choose calibrations at one or two points.
Detection of result stability.
Waterproof (IP67).
Automatic selection of the appropriate range.
Auto power off (30 minutes).
Different methods for measurement:
Immersion: You can analyze the sample in a beaker.
Sampling: Use it as a scoop to analyze the water.
Drops: LAQUAtwin meters can measure sample volumes as small as 0.05 ml by placing a drop of the sample on the sensor with a pipette.
Solid samples: Foods containing some moisture can be analyzed by placing a small piece directly on the sensor.
Powders: Simply place the powder sample on the sensor and pour the defined volume of deionized water on top.
Paper and textiles: If you want to analyze sheets of paper and textiles, cut the sample into small pieces and place it directly on the sensor. Pour the defined volume of deionized water on top.
Measurement in three easy steps:
1. Calibration: For a correct calibration, the sensor must be clean beforehand. If not, rinse it with water and put a little standard solution on the sensor and press the calibration button. A smiley face will appear as an indication that the calibration is complete. Clean the sensor with water until the calibration solution is removed and dry it with a soft, clean tissue.
2. Analysis: Only a tiny amount of sample is needed, so it is only necessary to fill the sensor and wait a few seconds until the smiley face appears.
3. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1500 measurements or when calibration cannot be performed. Sensors are sold separately and can be easily removed and replaced.
This sodium meter is supplied with:
2 CR2032 batteries, 1 pipette, Instruction Manual and Quick Start Guide.
Storage case.
1 ppm calibration solution (14 ml).
Calibration solution at 10 ppm (14 ml).
TISAB solution 14 ml
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: RXW-T11- 868
Brand: ONSET
Reference: M-RSA
Brand: ONSET
Reference: Evolution-M
Reference: EBD20
Brand: CODA SENSORS
Reference: V5D (2G-60)
Brand: FRIGGA
Reference: 38580
Brand: Innoquest, Inc.
Reference: BHW-PRO
Brand: ONSET
Reference: RK520-01-4-20mA
Brand: RIKA SENSORS
Reference: CTV-A
Brand: ONSET
Reference: U23-003
Brand: ONSET
Reference: MYJ-PHBYX12VW2
Brand: MYJ Sensores
Reference: DS1402D-DR8+
Brand: iBUTTON MAXIM INTEGRATED
Reference: RK300-02B
Brand: RIKA SENSORS
Reference: M-TPB-KIT
Brand: ONSET
Reference: U5841G
Brand: COMET
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
LAQUAtwin F‐11 Fluoride Ionometer
It is a fluoride meter used in a wide variety of analyses and measurements. It measures fluoride reliably and is very easy to use. It takes only a few seconds to give a result, making it an ideal instrument for field analysis.
Especificaciones:
check_circle
check_circle