AD/A Pressure Transducer for Atmospheric and Barometric Air Pressure for Surface Mounting
  • AD/A Pressure Transducer for Atmospheric and Barometric Air Pressure for Surface Mounting
  • AD/A Pressure Transducer for Atmospheric and Barometric Air Pressure for Surface Mounting
  • AD/A Pressure Transducer for Atmospheric and Barometric Air Pressure for Surface Mounting

AD/A Pressure Transducer for Atmospheric and Barometric Air Pressure for Surface Mounting, 0-10 V or 4-20 mA

AD/A-I

AD/A Surface Mount Atmospheric and Barometric Air Pressure Transducer, 0-10 V or 4-20 mA

  • 500...1150 mbar
  • menu input altitude above sea level
  • 0-10V, 4-20mA
  • hinge lock technology
CHOOSE MODEL
Description

The pressure transducer AD/A registers the atmospheric or barometric pressure in the range of 500...1150 mbar and converts this measured value into a linear output signal 0-10 V respectively 4-20 mA. As an option the pressure transmitter has a potential-free changeover contact and a backlit display. The display content can be rotated in 90° steps using a menu and the actual value, the switching threshold set, the state of the relay, the MIN/MAX measured values for the selected intervals(1 h / 6 h / 12 h / 24 h) etc. can be read out. On the display version the altitude above sea level cab be entered and switched between atmospheric and barometric air pressure. The atmospheric air pressure is defined by the weather conditions and the altitude above sea level. The barometric air pressure is defined by the weather conditions and normalised according to the altitude above sea level. If required the pressure transducer can be finely calibrated in site using an SPAN controller.

AVAILABLE MODELS
Article Number Pressure Output pressure  Version
AD/A-I 500...1150 mbar  4-20 mA  without display
AD/A-ID  500...1150 mbar 4-20 mA with display
AD/A-IR 500...1150 mbar 4-20 mA, changer without display
AD/A-IRD 500...1150 mbar 4-20 mA, changer with display
AD/A-U  500...1150 mbar  0-10 V  without display
AD/A-UD 500...1150 mbar 0-10 V with display
AD/A-UR  500...1150 0-10 V, changer  without display
AD/A-URD 500...1150 mbar  0-10 V, changer  with display

Technical Specifications

Pressure type: atmospheric air pressure / barometric air pressure (display version only)

Medium: air, non-aggressive, non-flammable, non-condensing gases

Measurement range atm. air pressure: 500-1150 mbar

Scales: 500...1150 mbar, 750...1150 mbar

Accuracy: ±5 mbar (at 20°C)

Temperature dependency: 1 mbar / 10 K

Linearity inaccuracy: ±1,0% final value

Pressure resistance: 5-times of measurement range

Sensor: Piezoresistive on-chip silicon sensor

Sensor protection: stainless steel sinter filter

Supply voltage analog 0-10 V: 24 V AC/DC (±5%)

Supply voltage analog 4-20 mA: 15...36 V DC (Ubmin = 15 V + RLoad*0,02A)

Current consumption at 0-10 V: typ. 15 mA, 30 mA peak current consumption for 50 ms at switching moment at option relay

Current consumption at 4-20 mA: max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching moment at option relay

Analogue output 0-10 V: 3-wire connection, min. load resistance 100 kOhm

Analogue output 4-20 mA: 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub - 15 V) / 0,02 A

Alarm output: 1 x potential-free change-over contact, 48 V, 1 A

Switching Hysteresis Relay: 2% of the selected scaling (without display), 0,5...5% of the selected scaling adjustable (with display)

Offset: max. ±50 mbar

Electrical connection: screw terminals max. 1,5 mm²

Display: optional LCD display with backlight on/off/auto

Output attentuation: 0 s / 1 s / 5 s / 10 s selectable by DIP switch

Cable gland: PG11 high-strength cable gland with strain relief

Housing: Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003

Dimensions: Housing: L 89 x W 80 x H 47 mm

Protection type: IP30

Protection class: III

Working range r.H.: 0...98% r.H. in contaminant-free, non-condensing air

Working temperature: 0...+50°C

Storage temperature: 0...+50°C

Installation: screw fastening

Approvals: CE, EAC, RoHS

Product Details
AD/A-I
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: DTP.1

Brand: Meatrol

DTP.1 Integrator for Rogowski Coils

(0)
DTP.1 Three phase DIN-RAIL 333mV output Integrator -Rated input:100A,600A,1kA,3kA,6kA(only choice one point,accept OEM) -Rated output:333mV rms -Rated coil ratio:50mV/kA or 85mV/kA(need to be define) -Accuracy:±0.5% (from 1% to 100% of rated ) -Bandwidth:30Hz to 5KHz -Power supply:12VDC Noted:each 100A only output maximum 1V

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...

Reference: U23-002A

Brand: ONSET

U23-002A HOBO® U23 Pro v2 Ext Temp/RH

(0)
U23-002A HOBO® U23 Pro v2 Ext Temp/RH Records temperature, humidity and dew point in both indoor and outdoor environments thanks to its external temperature and humidity sensor. Features Weatherproof housing for use in outdoor or condensing environments High accuracy Relative humidity sensor provides fast response and superior recovery from condensing...

Follow us on Facebook