RK500-06 ORP Sensor Water Quality Monitoring Sensor
PRODUCT DESCRIPTION
RK500-06 ORP sensor is simple and cost effective solution for a wide variety of waste water and process applications. This all-in-one sensor provides simultaneous measurement of ORP and temperature. The rugged Ryton body is designed for easy installation into on-line via the 3/4 inch tapered threaded connections provided on both ends of the sensor. The wide body sensors (26 mm diameter) hold four separate elements in one unbreakable Ryton body, large volume gelled electrolyte and the double junction reference system slows down depletion and poisoning extending the life time.
Item | Technical Specification |
ORP | |
Measurement Principle | Electrochemical(platinum ring) |
Range | -1500mV-+1500mV |
Resolution | 0.1mV |
Accuracy | ±0.5mV |
Supply | 7-30VDC |
Response time | 5s |
Output | 4-20mA & RS485 at the same time |
Operating Environment | -10-+80℃(<0.6MPa) |
Stability | ≤1%/year |
Maintenance | Every 1 months to clean the electrode, every 6 months calibrated |
Power consumption | <0.4W |
Ingress Protection | IP68 |
Storage | 10-60℃@20%-90%RH |
Cable length | 5m default, customizable |
DIMENSION
Type A
Universal type ABS housing, Up and down are NPT3/4 threads
Type B
Highly corrosion resistant PPS housing, Up and down are NPT3/4 threads
Type C
Standard glass type Length=120mm
Unit:mm
ELECTRODE MAINTENANCE & INSTALLATION AND FIXED
PH electrode is not used at ordinary times and can be soaked in 3mol/l KCL solution or saturated KCL solution. It is strictly prohibited to immerse the electrode in distilled water and deionize the water or tap water with minimal plasma content.If the PH electrode is contaminated with inorganic substances, it can be cleaned with 0.1mol/l Hcl or NaOH solution for a few minutes and then washed with distilled water. If the PH electrode is contaminated with organic substances, it can be cleaned with alcohol or acetone and then cleaned with distilled water.(note: the protective cap before the electrode should be removed when using);
Clean the electrode with tap water every 3 months or 6 months according to the working environment.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: SG-400
Brand: Apogee Instruments
Reference: TR-51i
Brand: TandD
Reference: UA-004-64
Brand: ONSET
Reference: S-WSET-B
Brand: ONSET
Reference: U20L-01
Brand: ONSET
Reference: RK300-03B
Brand: RIKA SENSORS
Reference: K-600N
Brand: BOSEAN
Reference: RK520-02
Brand: RIKA SENSORS
Reference: BH-4S
Brand: BOSEAN
Reference: TR-72nw-S
Brand: TandD
Reference: SQ-301X-SS
Brand: Apogee Instruments
Reference: PX3PLX01
Brand: VERIS
Reference: U0541
Brand: COMET
Reference: PX3DLN01S
Brand: VERIS
Reference: MX1105
Brand: ONSET
Reference: 41430
Brand: Innoquest, Inc.
RK500-06 ORP Sensor Water Quality Monitoring Sensor
check_circle
check_circle