- New
Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: VH400-2M
Brand: VEGETRONIX
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
STP01 Soil Temperature Sensor
STP01 accurately measures the temperature profile of the soil at 5 depths close to its surface. It is used for scientific grade surface energy balance measurements. The sensor is buried and usually cannot be taken to the laboratory for calibration. The on-line self-test using the incorporated heating wire offers a solution to verify STP01’s measurement stability.
Measurand | temperature at 5 depths from 0 to 0.5 m |
Measurement range | 30 to +70 °C |
Temperature sensors | matched thermocouples type T |
Uncertainty of temperature difference measurement | 1.5 % of measured value plus measurement system uncertainty in x 10⁻⁶ V/40 |
Uncertainty of relative position | ± 0.001 m |
Rated operating environment | surrounded by soil |
On-line functionality testing | self-test using the incorporated heater |
Reference temperature sensor | Pt100, IEC 751:1983 class B |
Sensor foil thickness | 0.6 x 10⁻³ m, 2.5 x 10⁻³ m at Pt100 |
Measurement depths | 0.02, 0.05, 0.1, 0.2 and 0.5 m |
Standard cable length (2 cables) | 5 m (see options) |
IP protection class | IP67 |
Optional non-traceable measurand | thermal conductivity at 3 depths |
Heater specifications | : |
Heater rated power supply | 9 to 15 VDC |
Power consumption daily average | 0.005 W |
Interval between self-tests | 24 h |
Self-test duration | 600 s |
Order code | STP01/cable length in m |
Options
Improved accuracy & quality assurance
STP01 soil temperature profile sensor offers an accurate temperature difference measurement at five measurement locations at 0.02, 0.05, 0.1, 0.2 and 0.5 m below the soil surface. It also has a well specified and fixed distance between the measurement locations. STP01 contains 5 matched thermocouples, at locations A to E in figure 5, and one reference temperature sensor (Pt100 type) at location E at 0.5 m depth. By having the reference temperature measurement in the sensor and only measuring differential thermocouple voltages (relative to the reference at 0.5 m), the uncertainty of the temperature difference measurement is very low: ± 0.02 °C is attainable. Simple copper-conductor signal wire is used in STP01’s cable. As an extra, a heating wire is incorporated in STP01. Analysis of the temperature change during the heating interval serves as a self-test. Soil temperature sensors are preferably left in the soil for as long as possible, so that the soil properties become representative of natural conditions. Using self-testing, the user no longer needs to take sensors to the laboratory to verify their stable performance. The result is a much improved accuracy & quality assurance of the measurement relative to measurements with conventional sensor types.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: T72 Pro (5G)
Brand: FRIGGA
Reference: ME440-No Rogoswki coils
Brand: Meatrol
Reference: 57080205 1gr
Brand: FUEL CELL
Reference: ORP‐11LAQUAtwin
Brand: HORIBA LAQUAtwin
Reference: PX3UXX05
Brand: VERIS
Reference: ZRC-50
Brand: Meatrol
Reference: GTA Sensor de temperatura
Brand: NESA
Reference: DC1
Brand: ECOMATIK
Reference: LS195
Brand: LINSHANG
Reference: S051
Brand: HORIBA LAQUAtwin
Reference: MX2306
Brand: ONSET
Reference: DV-DENDRO
Brand: ECOMATIK
Reference: 12120022
Brand: FUEL CELL
Reference: 12120044
Brand: FUEL CELL
Reference: VW0420
Brand: RST
check_circle
check_circle