Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
All best sellers
  • PAYMENT METHODS

  • New
U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem
  • U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem
  • U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem
  • U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem
  • U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem
  • U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem

U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem

U5841M

U5841M Data logger for 3 Voltage inputs 0-10V and 1 two-State input, with Built-in 2G Modem

GSM datalogger is designed to record 3 voltage inputs and 1 binary input. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.

It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.

GSM recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

Description

Technical data

Measured value

Voltage

Two-state signal

VOLTAGE INPUT

Measuring range 0 to 10 V DC
Accuracy ±10 mV
Input resistance approx. 130 Ω


BINARY INPUT

Parameters of the voltage contact „L“ level input voltage:< 0,8 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 2 MOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s


GSM MODEM PARAMETERS

Quad-band 850/900/1800/1900MHz
Compliant to GSM Phase2/2+
GPRS GPRS mobile station class B
Class 4 2W @ 850/900MHz
Class 1 1W @ 1800/1900MHz



GENERAL TECHNICAL DATA

  • Operating temperature: -20 to +60 °C
  • Channels: 3x current input, 1x binary input
  • Memory: 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode
  • Recording interval to the internal memory: adjustable from 1 second to 24 hours
  • Recording interval: to the COMET Cloud from 5 minutes
  • Interval for measuring and evaluating alarms adjustable: 1 s, 10 s, 1 min
  • Recording mode noncyclic: - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
  • Real time clock: year, leap year, month, day, hour, minute, second
  • Power rechargeable Li-Ion battery: A8200, 3.6V/5200mAh
  • Protection class: IP20
  • Dimensions: 61 x 93 x 53 mm, with antenna 120 x 93 x 53 mm
  • Weight (including batteries): approx. 270 g
  • Warranty: 3 years
Product Details
U5841M
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: MQ21

Brand: Meatrol

MQ21 Energy Quality Analyzer

(0)
MQ21 Energy Quality Analyzer -Power supply: Electricity from major loop, 90~528VAC or External 18650 lithium battery (not included) -Harmonic: 51 times simultaneously -16GB Micro SD card, USB Data Download -Communication: Modbus TCP &amp; Modbus RTU -Supported current sensor: Rogowski coil; Voltage-output current clamp -3 Rated current optional:...

Reference: SFT Sensor de flujo de calor

Brand: NESA

SFT Heat flow sensor between two surfaces

(0)
Sensor especially indicated in agrometeorology for determining the heat flow in the soil, important for controlling germination, rooting or development of pathogenic elements for crops, in geology for defining the state of soil thawing and the analysis of thermal equilibrium, etc.

Reference: LS177

Brand: LINSHANG

LS177 Large Aperture Spectrocolorimeter

(0)
LS177 large aperture spectrocolorimeter adopts D/8 illumination geometry, with 50mm large test aperture, specialized in color measurement and color comparison of non-transparent materials such as powder, masterbatches and so on. The spectrocolorimeter not only has various  color spaces and color difference formulas, but also can display spectral...

Reference: SF-HP

Brand: ECOMATIK

SF-HP Heat-Pulse Sap Flow Sensors

(0)
SF-HP Heat-Pulse Sap Flow Sensors Just as with TDP sap flow flow sensors, heat-pulse sap flow sensors also work on a temperature-based measuring principle. A major difference, however, is that HP sap flow sensors do not require continuous heating, but only a short heat pulse of a few seconds is applied. Depending on the measurement method used, the...

Reference: MRC-16

Brand: Meatrol

MRC-16 Mini flexible Rogowski coil

(0)
Advantage*Excellent linearity*Wide dynamic range* Not damaged by large overloads* Excellent degree of rejection to the externalcurrent conductor* No danger from open-circuited secondary* Zero power consumption* Small position error* Soft and light, easy to install* Long-term stability* Wide dynamic range* IP67 protection level

Reference: BH-4AS

Brand: BOSEAN

BH-4AS Portable Multi-gas Detector

(0)
BH-4AS Portable Multi-gas Detector BH-4AS portable multi-gas detector could detect combustible gas, O2 and other two types toxic gases continuously and simultaneously. It is widely used in the area where explosion-proof is required or toxic gas leaks, like underground channels or mining industry, so as to protect the workers' life and avoid damage on the...

Follow us on Facebook