LAQUAtwin case that includes:
LAQUAtwin NO3-11 Nitrate Ionometer
LAQUAtwin Ca-11 Calcium Ionometer
LAQUAtwin Na-11 Sodium Ionometer
LAQUAtwin K-11 Potassium Ionometer
Key Features:
Temperature compensation.
Automatic calibration: Recognizes calibration solutions. User can choose one- or two-point calibrations.
Result stability detection.
Waterproof (IP67).
No reagents used.
Automatic selection of appropriate range.
Auto power off (30 minutes).
Different methods for measurement:
Immersion: You can analyze the sample in a beaker.
Sampling: Use it as a scoop to analyze water.
Drops: LAQUAtwin meters can measure sample volumes as small as 0.05 ml by placing a drop of the sample on the sensor with a pipette.
Solid samples: Foods containing some moisture can be analyzed by placing a small piece directly on the sensor.
Powders: Simply place the powder sample on the sensor and pour the defined volume of deionized water on top.
Paper and fabric: If you want to analyse sheets of paper and fabric, cut the sample into small pieces and place it directly on the sensor. Pour the defined volume of deionised water over it.
Measurement in three easy steps:
1. Calibration: For a correct calibration, the sensor must be clean beforehand. If not, rinse it with water and put a little standard solution on the sensor and press the calibration button. A smiley face will appear to indicate that the calibration is complete. Clean the sensor with water until the calibration solution is removed and dry it with a soft, clean cloth.
2. Analysis: Only a tiny amount of sample is required, so it is only necessary to fill the sensor and wait a few seconds until the smiley face appears.
3. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1500 measurements or when calibration is no longer possible. Sensors are sold separately and can be easily removed and replaced.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: 514-20
Brand: HORIBA LAQUAtwin
Reference: B9Z
Brand: FRIGGA
Reference: RK500-11
Brand: RIKA SENSORS
Reference: SQ-515-SS
Brand: Apogee Instruments
Reference: FS-600
Brand: BOSEAN
Reference: LS225+N2000
Brand: LINSHANG
Reference: RTR503B
Brand: TandD
Reference: 12120025
Brand: FUEL CELL
Reference: ZL6 BASIC
Brand: METER GROUP
Reference: PQ-612
Brand: Apogee Instruments
Reference: 100.073 - acc.
Brand: PRONAMIC
Reference: RK200-02A+0-5 v+5 metros cable
Brand: RIKA SENSORS
Reference: U3121
Brand: COMET
Reference: 12120036
Brand: FUEL CELL
Reference: EC220
Brand: HORIBA LAQUAtwin
Reference: ME131M
Brand: Meatrol
LAQUAtwin case that includes:
LAQUAtwin NO3-11 Nitrate Ionometer
LAQUAtwin Ca-11 Calcium Ionometer
LAQUAtwin Na-11 Sodium Ionometer
LAQUAtwin K-11 Potassium Ionometer
check_circle
check_circle