
Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: VH400-2M
Brand: VEGETRONIX
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
U6841 Data logger for 3 current inputs 0-20mA and 1 two-state input
Datalogger is designed to record 3 current inputs and 1 binary input.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
In case of exceeded set limits alarms are indicated by LED, LCD and acoustically by built-in beeper.
Recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Included in delivery:
U6841
Manual
Traceable calibration certificate
Technical support at discussion forum
FREE analytical software COMET Vision
Technical data
Measured value
Current
Two-state signal
CURRENT INPUT
Measuring range 0 to 20 mA DC
Resolution better than 1 µA
Accuracy ±20 µA
Input resistance approx. 100 Ω
Minimum current 0 mA (open circuit)
Maximum current limited to approx. 40 mA
BINARY INPUT
Parameters of the voltage contact „L“ level input voltage:< 0,8 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 2 MOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s
GENERAL TECHNICAL DATA
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: RK200-07 0-2V
Brand: RIKA SENSORS
Reference: TR-55i-TC
Brand: TandD
Reference: PX3DXX02S
Brand: VERIS
Reference: TMC6-HE
Brand: ONSET
Reference: M1300
Brand: COMET
Reference: INTEGRADOR S10 MINI
Brand: Meatrol
Reference: RTR-602ES
Brand: TandD
Reference: LS170
Brand: LINSHANG
Reference: 11060016
Brand: FUEL CELL
Reference: 11060020 - 10x10
Brand: FUEL CELL
Reference: SF-HP
Brand: ECOMATIK
Reference: 57080182 1gr
Brand: FUEL CELL
Reference: Y031L
Brand: HORIBA LAQUAtwin
Reference: PX3ULX05
Brand: VERIS
U6841 Data logger for 3 current inputs 0-20mA and 1 two-state input
Datalogger is designed to record 3 current inputs and 1 binary input.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
In case of exceeded set limits alarms are indicated by LED, LCD and acoustically by built-in beeper.
Recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Included in delivery:
U6841
Manual
Traceable calibration certificate
Technical support at discussion forum
FREE analytical software COMET Vision
check_circle
check_circle