Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock

Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock
All best sellers
  • PAYMENT METHODS

M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ
  • M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 MYJ

M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 Thermocouple inputs

M1220

 M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 Thermocouple inputs

Universal datalogger with 4 inputs. Two inputs for temperature-humidity probes and two inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Data logger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

Quantity

Description

Technical data

Measured value

Temperature
Relative humidity
Counted values (dew point…)


TEMPERATURE SENSOR - external probe Pt1000

Measuring range -200 to +600 °C
Accuracy ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C
Resolution 0.1 °C


TEMPERATURE+HUMIDITY SENSOR - external probe T+RH DIGI

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C


DEW POINT

Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C



TEMPERATURE SENSOR - thermocouple K, N

Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C




TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C



TEMPERATURE SENSOR - thermocouple S

Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR - thermocouple B

Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C


TEMPERATURE SENSOR - thermocouple T

Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C



DC VOLTAGE

Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV





GENERAL TECHNICAL DATA

Operating temperature -10 to +60 °C
Channels 4x external temperature probe
Counted values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Memory 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
Recording interval 1s to 24 hours
Display and alarm refresh each 10 s
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Available temperature units degrees Celsius, degrees Fahrenheit
Communication interface Ethernet, USB, RS232
Ethernet communication protocols WWW, SNMPv1, XML, DATALINK
Alarm protocols E-Mail
Power AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)
Battery life 3 - 4 weeks
Protection class IP20
Dimensions (without connectors) 178 x 95 x 37mm, without attached cables
Weight (including batteries) approx. 380 g
Warranty 3 years

Features

Up to 4 physical inputs - 2x MiniDin + 2x Thermocouple


  • Pt1000 temperature probes with built-in configuration memory (xxx/M series)
  • Temperature/relative humidity probes with digital output - DigiS/M, DigiL/M, DIGIH/M
  • The probes are interchangeable without calibration to a specific device and regardless of the cable length. The cable length can be 1, 2, 5, 10, 15 meters.
  • Thermocouple probe K, J, S, B, T, N
  • Direct input of bipolar voltages with range up to -60 to +140 mV
  • Sensors with voltage output (range -60 to +140 mV; accuracy ±100 µV or -18 to +18 mV; accuracy ±20 µV)









Evaluation of up to 16 variables

Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be an additional expression of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can also be the result of conversions between channels, e.g. the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The recording mode can be set as non-cyclic, when recording stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

The measured values ​​are displayed on the display with backlight option and the ability to change the size of the display digits.





Power supply

Multilogger can be operated from an AC adapter or from rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and enable recording and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.





Alarm limits and alarm indication


It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signalling can be acoustic (built-in buzzer), optical, by sending an alert by email or an alarm output. The alarm output is for connecting an external visual or audio alarm.









Communication interfaces




  • Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries.
  • Multilogger - Alarm limits

  • sends an email when an alarm state begins or ends
  • uses DATALINK: displays current values ​​or downloads values ​​from memory to the COMET database on your PC. The COMET Database software contains many useful tools for data analysis: graphs, tables, statistics, etc.
  • Simple wireless communication with TP-LINK Wi-Fi router
  • Third-party apps to read actual measured values ​​using universal SNMPv1 and XML protocols
  • View current measured values ​​using your web browser






ALARM OUT output

  • The output can be used to control other devices when the alarm is triggered, such as an external buzzer, telephone dialer, etc.
  • Output type: Open collector transistor
  • Maximum switching current: 100 mA
  • Maximum switching current: 100 mA Output voltage: 24 Vuxiliary voltage at terminal: +5 V (only when mains power is present)
  • Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated by an internal buzzer, 3 LEDs, or email alerts via the Ethernet port.
Product Details
M1220
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: SOIL-PRO-T

Brand:

SOIL-PRO-T Soil Temperature Profiler

(0)
The SOIL-PRO-T temperature probe is equipped with seven 1/3 DIN Pt100 sensors to measure temperature at depths of: +5 cm, 0, -5 cm, -10 cm, -20 cm, -50 cm, -1 m above ground level, as indicated by the World Meteorological Organization (WMO).The fiberglass tube guarantees perfect waterproofing and high thermal insulation along the vertical axis. The RS485...
More
In stock

Reference: LAQUA‐EC210‐K

Brand: HORIBA LAQUAtwin

LAQUA‐EC210‐K EC 210 Portable Conductivity Meter (Series 200)

(0)
LAQUA‐EC210‐K EC 210 Portable Conductivity Meter (Series 200) Measures conductivity, salinity, resistivity, total dissolved solids (TDS) and temperature. Features IP67 protection system. Backlit LCD display that allows simultaneous reading of conductivity, actual sample temperature and measurement duration. Automatic scale change to obtain the reading...
Price €500.00
More
In stock

Reference: V5D (2G-60)

Brand: FRIGGA

V5D (2G-60) Real-time Temperature Positioning Monitor (Single-use)

(0)
V5D (2G-60) Real-time Temperature Positioning Monitor (Single-use) InformationTemperature, Weak Light, LocationNew generation of global real-time temperature monitorData is stored in the cloud for traceability; USB port for backup PDF data downloadFull cold chain visibility(Location, Temperature, Light, Route) via Frigga cloudImprove transportation...
More
In stock

Reference: T5245

Brand: COMET

T5245 CO2 concentration transmitter with 0-10 V output, duct mount

(0)
Duct-mounted CO2 concentration transmitter with 0-10 V output. Green LED lights up: CO2 concentration 0 to 1000 ppm Yellow LED lights up: CO2 concentration 1001 to 1200 ppm Red LED lights up: CO2 concentration 1201 ppm and above Measuring range can be extended for an additional charge:Measuring range: 0 to 10,000 ppm Accuracy: 100 ppm + 5 % of measured...
Price €369.00
More
In stock

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock

Reference: ME231

Brand: Meatrol

ME231 Three-phase Multifunctional Smart Meter MEATROL

(0)
ME231 Multifunction Smart Meter DIN-RAIL Communication: MODBUS-RS485 Power supply: 85-240V Harmonic: 50 times meanwhile Harmonic display Without recorder 6 Tariff One relay output, one digital input Connect:rogowski coil and 333mV Cts with VT up to 500kV Rated current:10A,100A,500A,1000A,3000A,6000A(Widely adapted to a variety of Rogowski coil and can be...
Price €190.00
More
In stock

Reference: FS6003-MBR-A1B1H1R1T1W1W2-G

Brand: FUEHLER SYSTEME

FS6003-MBR-A1B1H1R1T1W1W2-G Compact weather station, digital output (Modbus RTU)

(0)
Description:  Precipitation: yes/no Brightness: 0-150 kLux Twilight: 0-999 Lux Wind speed: 1-40 m/s Wind direction: 1-360° Temperature: -30...+60°C Humidity: 0-100% r.H. Global radiation: 0-1300 W/m² Air pressure: 300-1100 hPa Weight: 550 g Optional Accesories ZM/O-91 Cable for FS6003 - 10m  ZM/O-65 - FS6003 mounting angle
Price €1,195.00
More
In stock