M1220 Multilogger - Thermo hygro meter with 2 MiniDIN and 2 Thermocouple inputs
Universal datalogger with 4 inputs. Two inputs for temperature-humidity probes and two inputs for thermocouples K, J, S, B, T, N.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Data logger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
Technical data
Measured value
Temperature
Relative humidity
Counted values (dew point…)
TEMPERATURE SENSOR - external probe Pt1000
Measuring range -200 to +600 °C
Accuracy ±0.2 °C (-200 to +100 °C);
±0.2 % from reading from +100 to +600 °C
Resolution 0.1 °C
TEMPERATURE+HUMIDITY SENSOR - external probe T+RH DIGI
Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C
DEW POINT
Measuring range according to the connected probe Digi/M
Accuracy according to the connected probe Digi/M
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple K, N
Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple J
Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple S
Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple B
Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C
TEMPERATURE SENSOR - thermocouple T
Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
DC VOLTAGE
Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV
GENERAL TECHNICAL DATA
Operating temperature -10 to +60 °C
Channels 4x external temperature probe
Counted values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Memory 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
Recording interval 1s to 24 hours
Display and alarm refresh each 10 s
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Available temperature units degrees Celsius, degrees Fahrenheit
Communication interface Ethernet, USB, RS232
Ethernet communication protocols WWW, SNMPv1, XML, DATALINK
Alarm protocols E-Mail
Power AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)
Battery life 3 - 4 weeks
Protection class IP20
Dimensions (without connectors) 178 x 95 x 37mm, without attached cables
Weight (including batteries) approx. 380 g
Warranty 3 years
Features
Up to 4 physical inputs - 2x MiniDin + 2x Thermocouple
Evaluation of up to 16 variables
Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values can be an additional expression of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can also be the result of conversions between channels, e.g. the difference of two connected temperature probes.
The measured values are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The recording mode can be set as non-cyclic, when recording stops after filling the memory, or cyclic, when after filling the memory the oldest stored values are overwritten with the new ones.
The measured values are displayed on the display with backlight option and the ability to change the size of the display digits.
Power supply
Multilogger can be operated from an AC adapter or from rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.
While using the AC adapter, the batteries provide backup operations and enable recording and measurement during a power outage. Thanks to the Ethernet output, the device reports the failure via an e-mail message.
Alarm limits and alarm indication
It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).
Alarm signalling can be acoustic (built-in buzzer), optical, by sending an alert by email or an alarm output. The alarm output is for connecting an external visual or audio alarm.
Communication interfaces
ALARM OUT output
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: BASE-U-4
Reference: TA Sensor de temperatura
Reference: M-RSA
Brand: ONSET
Reference: PX3DLN01S
Brand: VERIS
Reference: VH400-2M
Brand: VEGETRONIX
Reference: DS1402D-DR8+
Brand: iBUTTON MAXIM INTEGRATED
Reference: AC-422
Brand: Apogee Instruments
Reference: ORP‐11LAQUAtwin
Brand: HORIBA LAQUAtwin
Reference: MQ31
Brand: Meatrol
Reference: HF03-LI19
Brand: Hukseflux
Reference: STP-5
Brand: Meatrol
Reference: M1200E
Brand: COMET
Reference: ST2424
Brand: MAE
Reference: TR-55i-P
Brand: TandD
Reference: Affinity Gateway
check_circle
check_circle