Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
All best sellers
  • PAYMENT METHODS

  • New
M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs MYJ
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs
  • M1300 Ethernet Multilogger - universal datalogger with 4 inputs

M1300 Ethernet Multilogger - universal datalogger with 4 inputs

M1300

 M1300 Ethernet Multilogger - universal datalogger with 4 inputs

Battery powered datalogger with 4 universal inputs for measurement of 0-10V voltage, 0-20mA current, two-state signal and for counting pulses.
Signals are connected to four detachable terminal blocks.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its Inputs.
Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

Description

Technical data

Measured value

Current
Voltage
Two-state signal
Pulses

DC VOLTAGE

Measuring range 0 to 10 V
Accuracy ±10 mV
Resolution better than 100 µV

DC CURRENT

Measuring range 0 to 20 mA
Accuracy ±20 µA
Resolution better than 0,1 µA

BINARY SIGNAL

Input voltage for level “switched on”/ <0,4 V/> 2 V
Minimum/maximum input voltage 0 V/+30 V DC
I mpedance of the “switched on”/ < 10 kOhm/> 300 kOhm



COUNTER INPUT

Range of counter 24 bit (16 777 215) the counter overflow can be allowed
Maximum input frequency 200 Hz





GENERAL TECHNICAL DATA

  • Operating temperature: -10 to +60 °C
  • Channels: 4x binary, counter, voltage and current input
  • Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
  • Recording interval: 1s to 24 hours
  • Display and alarm refresh: each 10 s
  • Recording mode: noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
  • Available temperature units: degrees Celsius, degrees Fahrenheit
  • Communication interface: Ethernet, USB, RS232
  • Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK
  • Alarm protocols: E-Mail
  • Power: AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)
  • Battery life: 3 - 4 weeks
  • Protection class: IP20
  • Dimensions (without connectors): 178 x 95 x 37mm, without attached cables
  • Weight (including batteries): approx. 380 g
  • Warranty: 3 years

Features

Up to 4 physical Inputs - TERMINALS

  • Sensors with voltage output (range 0-10 V; accuracy ±10 mV)
  • Sensors with current output (range 0-20 mA; accuracy ±20 µA)
  • Sevices with two-state output (potential-less contact or voltage signal 0-30V); may be applied to input 3 and 4
  • Devices with pulse signal (potential-less contact or voltage signal 0-30V); may be applied to input 4


Evaluation of up to 16 variables

Up to 16 variables may be calculated from the four connected probes / sensors. This is the sum of the measured and calculated values. The calculated values can be a further expression of moisture – dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can be also the result of inter-channel conversions, e.g. the difference of two connected temperature probes.

The measured values are stored in the internal non-volatile memory. Memory capacity is up to 1 million values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when after fulfilling the memory oldest stored values are overwritten by new ones.

Measured values are displayed on the screen with backlight option and the ability to change the size of display digits



Power supply



Multilogger can be powered by AC adapter or by rechargeable batteries with charging capability. Batteries are always a part of the device (you can also use standard alkaline AA batteries). Batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and provide recording and measurement during power failure. Thanks to the Ethernet output the device informs about the failure via e-mail message.




Alarm limits and alarm indication

It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signalization can be acoustic (built-in beeper), optical, sending an e-mail alert or an alarm output. The alarm output is for connecting an external audio or visual alarm.





Communication interfaces

Multilogger is always equipped with USB connector for communication, data analysis and also for charging of the rechargeable batteries.


  • send an e-mail when an alarm state starts or ends
  • use DATALINK: display current values or download values from memory to COMET Database in your PC. Software COMET Database contains many useful tools for data analysis - graphs, tables, statistics, etc.simple wireless communication with Wi-Fi TP-LINK router
  • third-party applications to read the actual measured values using universal protocols SNMPv1 and XML
  • view current measured values using your web browser





Output ALARM OUT

  • Output can be used for controling other devices when alarm is launched, such as external buzzer, telephone dialer etc.
  • Type of output - open collector transistor
  • Max. switching current - 100 mA
  • Max. voltage on output - 12 V
  • Auxiliary voltage at terminal - +5 V (only when the mains supply is present)
  • Users can receive alarms if the values go outside the paramters set. Alarms are indicated through an internal buzzer , 3 LEDs or email alerts via Ethernet port.

Product Details
M1300
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: UX100-003

Brand: ONSET

UX100-003 HOBO Temperature/Relative Humidity 3.5% Data Logger

(0)
UX100-003 HOBO Temperature/Relative Humidity 3.5% Data Logger With integrated sensors to measure and record temperature and relative humidity (within 3.5% accuracy) in indoor environments.  Important Information Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w/HOBOware Pro USB Drive software purchase).  What's...

Reference: CD4

Brand: BOSEAN

CD4 Mining Use Multi-gas Detector

(0)
CD4 Mining Use Multi-gas Detector The CD4 mining use multi gas detector adopts large-scale integrated circuit technology and complies with international intelligent technology standards. This detector uses catalytic and electrochemical gas sensors to detect gases through natural diffusion, with excellent sensitivity and repeatability. Convenient use and...

Reference: SC-1

SC-1 Leaf Porometer Stomatal Conductance

(0)
To measure stomatal conductance using the steady state technique. SC-1 Porometer Applications Water use and water balance. Measurement of water stress. Basic research in plant physiology. Herbicide assimilation. Assimilation of ozone and other polluting agents. Tests and comparative studies. Stomatic behavior.

Reference: DTP.1

Brand: Meatrol

DTP.1 Integrator for Rogowski Coils

(0)
DTP.1 Three phase DIN-RAIL 333mV output Integrator -Rated input:100A,600A,1kA,3kA,6kA(only choice one point,accept OEM) -Rated output:333mV rms -Rated coil ratio:50mV/kA or 85mV/kA(need to be define) -Accuracy:±0.5% (from 1% to 100% of rated ) -Bandwidth:30Hz to 5KHz -Power supply:12VDC Noted:each 100A only output maximum 1V

Reference: RCT-35

Brand: Meatrol

RCT-35 Rigid Rogowski coil

(1)
applications* Measuring devices, laboratory instrumentation.* Energy control and monitoring systems.* DC ripple measurement* Monitoring of harmonics and transients.* Power meter, power analyzer sensor

Follow us on Facebook