LAQUAtwin Ca‐11C‐1 LAQUAtwin iCa Checker Calcium Ionometer
it is a calcium meter used to measure Hypocalcemia in bovine blood. It measures calcium reliably and is very easy to use. It takes only a few minutes to give a result, making it an ideal instrument to know the health status of your cow.
Specifications:
Description
The wide measurement range (0.1 to 5.0 mmol/L) allows high concentrations to be measured without the need for dilution.
Uses:
- Evaluation of the calcium content in the blood of dairy cows.
This equipment incorporates a flat ion-selective electrode for microvolume measurement. The replaceable electrode uses the same measurement principle as the traditional calcium ion-selective electrode (ISE). It only requires a few drops (0.3 ml) to provide a fast and accurate analysis.
Main features:
Temperature compensation.
Automatic calibration: recognizes calibration solutions. The user can choose one- or two-point calibrations.
Detection of result stability.
Waterproof (IP67).
No reagents are used.
Automatic selection of the appropriate range.
Automatic shutdown (30 minutes).
Measurement in three simple steps:
1. Calibration: For a correct calibration, the sensor must be previously cleaned. If not, rinse it with cleaning solution and put some standard solution on the sensor and press the calibration button. A smiley face will appear as an indication that the calibration is complete. Wipe the sensor with cleaning solution until the calibration solution is removed and dry it with a soft, clean tissue.
2. Analysis: Only a minimal amount of sample is required, so you only need to fill the sensor and wait a few seconds until the smiley face appears.
3. Cleaning: Always keep the sensor clean.
Sensors should be replaced after approximately 1000 measurements or when calibration cannot be performed. Sensors are sold separately and can be easily removed and replaced.
This calcium meter comes in two formats:
OPTION A
2 CR2032 batteries, 1 wash bottle, Instruction Manual and Quick Start Guide.
Storage case.
1 1.25 mmol/L calibration solution (25 ml).
1 2.50 mmol/L calibration solution (25 ml).
1 Cleaning solution (250 ml).
OPTION B
2 CR2032 batteries, 1 wash bottle, instruction manual and quick start guide.
Storage case.
2 1.25 mmol/L calibration solution (25 ml).
2 2.50 mmol/L calibration solution (25 ml).
3 Cleaning solution (250 ml).
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: 12120020
Brand: FUEL CELL
Reference: TEROS 12
Brand: METER GROUP
Reference: STC-24
Brand: Meatrol
Reference: SQ-522-SS
Brand: Apogee Instruments
Reference: M-TPB-KIT
Brand: ONSET
Reference: LS125 + Sonda UVALED-X3
Brand: LINSHANG
Reference: HE171
Brand: HUATO
Reference: HF03-LI19
Brand: Hukseflux
Reference: K-11
Brand: HORIBA LAQUAtwin
Reference: 514-50
Brand: HORIBA LAQUAtwin
Reference: TMC6-HC
Brand: ONSET
Reference: DTP.1
Brand: Meatrol
Reference: RK310-02
Brand: RIKA SENSORS
Reference: U24-002-C
Brand: ONSET
Reference: EC220
Brand: HORIBA LAQUAtwin
LAQUAtwin Ca‐11C‐1 LAQUAtwin iCa Checker Calcium Ionometer
it is a calcium meter used to measure Hypocalcemia in bovine blood. It measures calcium reliably and is very easy to use. It takes only a few minutes to give a result, making it an ideal instrument to know the health status of your cow.
Specifications:
check_circle
check_circle