Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
All best sellers
  • PAYMENT METHODS

PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310
  • PlantPen PRI 210 and PlantPen NDVI 310

PlantPen Chlorophyll Meter NDVI and PRI

PlantPen NDVI 310

PSI's PlantPen is a reflectance-based device that provides a convenient, low-cost method of measuring the relative chlorophyll content of attached or detached leaves. PlantPens are hand-held, battery-powered devices that help to characterize plants by means of reflectance. PlantPens measure and calculate specific reflectance indices to monitor chlorophyll content, photoprotecting carotenoids, and other important aspects of live foliage. Two standard PlantPen versions measure the most common indexes: Photochemical Reflectance Index (PRI) and Normalized Difference Vegetation Index (NDVI.). Comprehensive FluorPen 1.1 software provides data transfer routines and many additional features for data presentation in tables and graphs.

CHOOSE MODEL
Description

PlantPen PRI 210 and PlantPen NDVI 310
PlantPen is a reflectance-based device that provides a convenient and low-cost method for measuring the relative photosynthetic pigment content of a leaf sample. PlantPens measure and calculate particular reflectance indices to assess chlorophyll content, photoprotective carotenoids, and other important characteristics in living foliage. Two standard versions of PlantPen measure the most common indices: Photochemical Reflectance Index (PRI) and Normalized Difference Vegetation Index (NDVI). Measured data are stored sequentially in FluorPen's internal memory. The comprehensive FluorPen 1.1 software provides data transfer routines and many additional features for data presentation in tables and graphs.
The PlantPen model PRI 210 measures the photochemical reflectance index (PRI) by comparing leaf reflectance in two narrow wavelength bands centered near 530 nm and 590 nm. The PRI is sensitive to changes in carotenoid pigments that are indicative of changes in photosynthetic light use efficiency, CO2 uptake rate, and as a reliable index of water stress. As such, it is used in vegetation productivity and stress studies.
The PlantPenmodel NDVI 310 measures the Normalized Difference Vegetation Index (NDVI), which is an important indicator of chlorophyll content in plants. The plant leaf pigment chlorophyll strongly absorbs visible light (0.4 to 0.7 µm) for use in photosynthesis. The cellular structure of leaves, on the other hand, strongly reflects near-infrared light (0.7 to 1.1 µm). Differences in plant reflectance in visible and near-infrared wavelengths are used to calculate the NDVI index. NDVI is directly related to the photosynthetic capacity and therefore the energy absorption of plant canopies.
APPLICATIONS:
Rapid detection of photosynthetic pigments
Early detection of stress
Effects on nutrition
Field studies
Agronomy and forestry
PLANT MEASUREMENT:
Normalized Difference Vegetation Index (NDVI)
NDVI = (RNIR – RRED ) / (RNIR + RRED )
PRI (Photochemical Reflectance Index)
PRI = (R530 – R590) / (R530 + R590)
SOFTWARE:
FluorPen 1.1 software (compatible with Windows 7 or higher)
Bluetooth and USB communication
Display routines and data transfer to Microsoft Excel (optional)
GPS mapping
Models Available:
PlantPen PRI 210: measures the Photochemical Reflectance Index (PRI) by comparing leaf reflectance in two narrow wavelength bands centered near 530 nm and 590 nm. The PRI is sensitive to changes in carotenoid pigments that are indicative of changes in photosynthetic light use efficiency, CO2 uptake rate, and as a reliable index of water stress. As such, it is used in vegetation productivity and stress studies.
PlantPen NDVI 310: Measures the Normalized Difference Vegetation Index (NDVI), which is an important indicator of chlorophyll content in plants. The plant leaf pigment chlorophyll strongly absorbs visible light (0.4 to 0.7 µm) for use in photosynthesis. The cellular structure of leaves, on the other hand, strongly reflects near-infrared light (0.7 to 1.1 µm). Differences in plant reflectance in visible and near-infrared wavelengths are used to calculate the NDVI index. NDVI is directly related to the photosynthetic capacity and therefore the energy absorption of the plant canopies.
Accessories
- Control and data unit for handheld devices
Small portable notebook (type according to current market availability).
- Spare USB communication cable
Spare USB cable that allows the connection between the "pen" type devices and a PC (the device is delivered with a USB cable, which is included in the price of the device).
- Self-adhesive rubber pads
A set includes 10 solid pads (for fixing to the clip) and 10 pads with an opening (for fixing to the optical head).

Product Details
PlantPen NDVI 310
Comments (0)
Grade
No customer reviews for the moment.
1 other product in the same category:

Reference: SpectraPen mini

Brand: Photon System Instruments (PSI)

SpectraPen mini Calibrated Spectroradiometer and Quantum Photometer

(0)
SpectraPen mini is a small, portable and affordable calibrated spectroradiometer and quantum light meter, which is controlled via mobile application. The SpectraPen mini measures spectral quality, light intensity and color. The device is calibrated for visible light in the range from 400 to 850 nm. The SpectraPen mini is ideal as a multi-purpose...

Follow us on Facebook