The LaiPen LP 110 measures leaf area index (LAI), defined as the one-sided green leaf area per unit area of ground surface (m2 per m2) in broadleaf tree canopies. The LaiPen LP 110 calculates LAI and other canopy structure attributes from solar radiation measurements made with a wide-angle optical sensor. Measurements made above and below the canopy are used to determine canopy light interception at five angles, from which LAI is calculated using a radiative transfer model in plant canopies.
The LaiPen LP 110 can operate in two operating modes:
Single-sensor mode: the reference measurement is taken before, after or during the measurement with the same instrument;
Two-sensor mode: a second instrument is used for automatic recording of the reference signal.
The LaiPen LP 110 measures leaf area index (LAI), defined as the one-sided green leaf area per unit area of ground surface (m2 per m2) in broadleaf tree canopies. The LaiPen LP 110 calculates LAI and other canopy structure attributes from solar radiation measurements made with a wide-angle optical sensor. Measurements made above and below the canopy are used to determine canopy light interception at five angles, from which LAI is calculated using a radiative transfer model in plant canopies.
The LaiPen LP 110 can operate in two operating modes:
Single-sensor mode: the reference measurement is taken before, after or during the measurement with the same instrument;
Two-sensor mode: a second instrument is used for automatic recording of the reference signal.
LAIPEN MEASURES
Leaf Area Index (LAI)
Photosynthetically Active Radiation (PAR):
Photosynthetically Active Radiation measured as Photosynthetic Photon Flux Density (PPFD)
APPLICATIONS
Studies of canopy growth and productivity
Studies of forest dynamism
Research on air pollution or insect impact on foliage health
Great for rapid, repeated measurements and for large plant screening programs
Remote sensing
Global carbon cycle
SOFTWARE
Comprehensive software with data collection, analysis and visualization
USB and Bluetooth communication
Visualization and data transfer routines to Microsoft Excel
Regular firmware updates
Integrated GPS module
Accessories
Mini computer
Small laptop computer (type according to current market availability).
Standard tripod
Tripod stand that offers the flexibility to choose the ideal location for automatic readings in open terrain.
Carrying rod
Rod for measuring above bushes and undergrowth.
Spare USB communication cable
Spare USB cable that allows the connection between the "pen" type devices and a PC (the device is delivered with a USB cable, which is included in the price of the device).
Key Features
TECHNICAL SPECIFICATION
Spectral range 340 nm - 790 nm (SP 110 UVIS) |
640 nm - 1050 nm (SP 110 NIR) |
Spectral response half width 9 nm (SP 110 UVIS) 8 nm (SP 110 NIR) |
Wavelength reproducibility +/- 0.5 nm |
Spectral Straylight -30 dB |
Integration time From 5 ms to 10 s |
Integrated Autoset function |
Number of pixel 256 |
Dynamic Range High gain: 1:4300 |
Low gain: 1:13000 |
Optical entrance SMA905 with 0.22 NA single-stand optical fiber |
SYSTEM SPECIFICATION |
Internal memory capacity 16 Mbit |
Internal data logging Up to 4,000 measurements |
Real time clock Yes |
Data transfer USB 2.0 |
PC software SpectraPen 1.1 (Windows 7 and higher) |
BATTERY |
Type Li-Ion rechargeable battery |
Capacity 2600 mAh |
Max. charging current 0.5 A |
Charging Via USB port - PC, power bank, USB charger, etc. |
Battery life 48 hours typical with full operation |
Low battery indicator |
GENERAL SPECIFICATION |
Display Touchscreen 240 x 320 pixel; 65535 colors |
Built in GPS module Ultra-high sensitivity down to -165 dBm |
High accuracy of <1.5 m in 50 % of trials |
Size 150 x 75 x 40 mm |
Weight 300 g |
Operating conditions Temperature: 0 to +55 °C |
Relative humidity: 0 to 95 % (non-condensing) |
Storage conditions Temperature: -10 to +60 °C |
Relative humidity: 0 to 95 % (non-condensing) |
Warranty 1 year parts and labor |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: RTR502B
Brand: TandD
Reference: SP-610-SS
Brand: Apogee Instruments
Reference: ELTS4224
Brand: RST
Reference: TR-74Ui-S
Brand: TandD
Reference: CL-355A
Reference: Wet&Dry + QA-PS20W
Reference: MX2304
Brand: ONSET
Reference: LPTPC-V
Brand: RST
Reference: SM-600+L-5
Brand: Apogee Instruments
Reference: U0141TG
Brand: COMET
Reference: LS193
Brand: LINSHANG
Reference: ST2424
Brand: MAE
Reference: DT4205
Brand: RST
Reference: PQ-610
Brand: Apogee Instruments
Reference: Quido Estación agrometeorológica
The LaiPen LP 110 measures leaf area index (LAI), defined as the one-sided green leaf area per unit area of ground surface (m2 per m2) in broadleaf tree canopies. The LaiPen LP 110 calculates LAI and other canopy structure attributes from solar radiation measurements made with a wide-angle optical sensor. Measurements made above and below the canopy are used to determine canopy light interception at five angles, from which LAI is calculated using a radiative transfer model in plant canopies.
The LaiPen LP 110 can operate in two operating modes:
Single-sensor mode: the reference measurement is taken before, after or during the measurement with the same instrument;
Two-sensor mode: a second instrument is used for automatic recording of the reference signal.
check_circle
check_circle