U0246 Temperature data Logger for 3x thermocouples, 1x External Pt1000 Probe and 1x internal Sensor
Datalogger is designed to record temperature from three thermocouples, one Pt1000 probe and one internal temperature sensor.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
In case of exceeded set limits alarms are indicated by LED, LCD and acoustically by built-in beeper.
The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Included in delivery:
U0246
Instruction manual
Traceable calibration certificate
1x 3.6V lithium battery
FREE FULL VERSION COMET Vision analytical software
EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY
USB COMMUNICATION CABLE IS NOT INCLUDED IN DELIVERY
Technical data
Measured value
Temperature
TEMPERATURE SENSOR - internal probe
Measuring range -30 to +70 °C
"Accuracy ±0.4°C;"
Resolution 0.1 °C
Response time of temperature measurement (temperature step 20°C, air flow approximately 1m/s) t63 < 6 minutes; t90 < 15 minutes
TEMPERATURE SENSOR - external probe Pt1000
Measuring range -200 to +260 °C
"Accuracy ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C"
Resolution 0.1 °C
"Response time t90 of temperature measurement (temperature step 20°C, air flow approximately 1m/s) according to the connected probe"
TEMPERATURE SENSOR - THERMOCOUPLE TYPE B, J, K, N, S, T
Measuring range type K and N -200 to +1300 °C
Measuring range type J -200 to +750 °C
Measuring range type S 0 to 1700 °C
Measuring range type B 250 to 1800 °C, cold junction is not compensated
Measuring range type T -200 to +400 °C
Measuring range of DC voltage -70 to +70 mV
Accuracy for types J, K, N, T ± (|0,3 % of the measurement value|+1,5 °C)
Accuracy for types B and S ± (|0,5 % of the measurement value| +5 °C)
Accuracy for DC voltage ± 70 µV
Resolution 0,1 °C
Response time according to the connected thermocouple
GENERAL TECHNICAL DATA
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: U0121M
Reference: H21-USB
Brand: ONSET
Reference: CDQ-T8A
Brand: CODA SENSORS
Reference: S700-EX- WIFI
Brand: HUATO
Reference: 41430
Brand: Innoquest, Inc.
Reference: W0911
Brand: COMET
Reference: W6810
Brand: COMET
Reference: RTR507BL
Brand: TandD
Reference: T0510
Brand: COMET
Reference: W3711
Brand: COMET
Reference: CDQ-T9A
Brand: CODA SENSORS
Reference: P3110E
Brand: COMET
Reference: HE2508 GSM MODEM
Brand: HUATO
Reference: Serie S500 RJ45
Brand: HUATO
Reference: RTR-576-S
Brand: TandD
U0246 Temperature data Logger for 3x thermocouples, 1x External Pt1000 Probe and 1x internal Sensor
Datalogger is designed to record temperature from three thermocouples, one Pt1000 probe and one internal temperature sensor.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
In case of exceeded set limits alarms are indicated by LED, LCD and acoustically by built-in beeper.
The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
check_circle
check_circle