Reference: UA-002-64

Brand: ONSET

UA-002-64 HOBO Pendant Temperature/Light 64K Data Logger

(0)
A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
Price €100.00
More
In stock

Reference: VH400-2M

Brand: VEGETRONIX

VH400 - Low-Cost Soil Moisture Sensors

(0)
VH400 Soil Moisture Sensor Probe Specifications Power consumption: < 13mA Supply Voltage: 3.5V to 20 VDC. Dimensions See drawing. Power on to Output stable: 400 ms Output Impedance: 10K ohms Operational Temperature: -40ºC to 85ºC Accuracy at 25°C: 2% Output: 0 to 3V related to moisture content Shell Color: Red Voltage Output Curves: Curves, Piecewise...
From Price €78.00
More
In stock
All best sellers
  • PAYMENT METHODS

M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ
  • M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN MYJ

M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN and 2 Terminals

M1322

M1322 Ethernet Multilogger - thermo-hygro-CO2 meter with 2 MiniDIN and 2 Terminals

Battery powered datalogger with built-in CO2 sensor and 4 universal inputs for measurement of temperature, humidity, 0-10V voltage, 0-20mA current, two-state signal and for counting pulses.
Multilogger can be installed permanently to Ethernet network or work as portable device.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

The device is designed for measuring and recording temperature, humidity, CO2 (internal sensor) with adjustable recording intervals from 1 second to 24 hours.

Datalogger can be connected to Ethernet. Then measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.

  • on-line monitoringcarbon dioxide   
  • recording of data
  • alarm warnings


Quantity

Description

Features

Up to 4 physical inputs - 2x TERMINALS + 2x MiniDin

Removable inputs allow connection of:


  • Sensors with voltage output (range 0-10 V; accuracy ±10 mV)
  • Sensors with current output (range 0-20 mA; accuracy ±20 µA)
  • Devices with dual-state output (potential-free contact or 0-30 V voltage signal); can be applied to input 3 and 4
  • Devices with pulse signal (potential-free contact or 0-30 V voltage signal); can be applied to input 4
  • Pt1000 temperature probes with built-in configuration memory (xxx/M series)
  • Temperature/relative humidity probes with digital output - DigiS/M, DigiL/M, DIGIH/M
  • Probes are interchangeable without calibration to a specific device and independently of cable length. Cable length can be 1, 2, 5, 10, 15 meters
  • Internal CO2 sensor with range 0 to 2000 ppm (custom range 0 to 10,000 ppm)





Evaluation of up to 16 variables

Up to 16 variables can be calculated from the four connected probes/sensors. This is the sum of the measured and calculated values. The calculated values ​​can be an additional expression of humidity: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can also be the result of conversions between channels, for example the difference of two connected temperature probes.

The measured values ​​are stored in the internal non-volatile memory. The memory capacity is up to 1 million values. The recording mode can be set as non-cyclic, when the recording stops after filling the memory, or cyclic, when after filling the memory the oldest stored values ​​are overwritten with the new ones.

The measured values ​​are displayed on the display with backlight option and the possibility of changing the size of the display digits



Power supply

Multilogger can be operated with an AC adapter or with rechargeable batteries with charging capacity. The batteries are always part of the device (you can also use standard AA alkaline batteries). The batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and allow recording and measurement during a power failure. Thanks to the Ethernet output, the device reports the fault via an e-mail message.


Alarm limits and alarm indication

It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signaling can be acoustic (built-in buzzer), optical, sending an alert by e-mail or an alarm output. The alarm output is for connecting an external visual or audio alarm.


Communication interfaces

Multilogger is always equipped with a USB connector for communication, data analysis and also for charging the rechargeable batteries. Multilogger - Alarm limits

  • Sends an e-mail when an alarm state begins or ends
  • Uses DATALINK: displays current values ​​or downloads values ​​from memory to the COMET database on your PC. The COMET Database
  • software contains many useful tools for data analysis: graphs, tables, statistics, etc.
  • Simple wireless communication with TP-LINK Wi-Fi router
  • Third-party applications to read actual measured values ​​using universal SNMPv1 and XML protocols
  • View current measured values ​​using your web browser





ALARM OUT output

  • The output can be used to control other devices when the alarm is triggered, such as an external buzzer, telephone dialer, etc.
  • Output type: open collector transistor
  • Maximum switching current: 100 mA
  • Maximum voltage at output: 24 V
  • Auxiliary voltage at terminal: +5 V (only when mains supply is present)
  • Users can receive alarms if values ​​go outside the set parameters. Alarms are indicated via an internal buzzer, 3 LEDs or email alerts via the Ethernet port.
Product Details
M1322
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: K-600

Brand: BOSEAN

K-600 4 in 1 Multi Gas Detector

(0)
K-600  4 in 1 Multi Gas Detector K-600 gas detector with built-in pump, robust for industrial use for utility workers, refinery workers, firefighters, maintenance engineers, those who spend time in sewers and waterworks, underground storage tanks, oil rigs, in tanks and silos in the maritime industry, and many others who need personal protective equipment.
More
In stock

Reference: TRC-24

Brand: Meatrol

MINI Flexible Rogowski coil Precision type TRC-16

(0)
TRC is a MINI flexible current transducer based on Rogowski principle, particularly suitable for measurement incombination with portable devices. MRC coils are available in different sizes and can be supplied according tocustomer’s design, therefore they can be used in all those applications, in which traditional transducers are not fittingdue to its size...
From Price €57.00
More
In stock

Reference: BH-4AS

Brand: BOSEAN

BH-4AS Portable Multi-gas Detector

(0)
BH-4AS Portable Multi-gas Detector BH-4AS portable multi-gas detector could detect combustible gas, O2 and other two types toxic gases continuously and simultaneously. It is widely used in the area where explosion-proof is required or toxic gas leaks, like underground channels or mining industry, so as to protect the workers' life and avoid damage on the...
More
In stock

Reference: T5245

Brand: COMET

T5245 CO2 concentration transmitter with 0-10 V output, duct mount

(0)
Duct-mounted CO2 concentration transmitter with 0-10 V output. Green LED lights up: CO2 concentration 0 to 1000 ppm Yellow LED lights up: CO2 concentration 1001 to 1200 ppm Red LED lights up: CO2 concentration 1201 ppm and above Measuring range can be extended for an additional charge:Measuring range: 0 to 10,000 ppm Accuracy: 100 ppm + 5 % of measured...
Price €369.00
More
In stock

Reference: LS126A

Brand: LINSHANG

LS126A UV Light Meter

(0)
LS126A UV Light Meter Suitable for UV LED curingUltra-small probe, narrowest width of 7.2mmWide spectral range: 340nm-420nmWith a high-speed sampling speed of 2048 times per second
Price €895.00
More
In stock

Reference: RK330-01B

Brand: RIKA SENSORS

RK330-01B Atmospheric Temperature, Humidity & Pressure Sensor

(0)
RK330-01B Atmospheric Temperature, Humidity & Pressure Sensor Tº Range:-40~60°C,Resolution:0.1°C,Accuracy:±0.5°C RH Range:0-100%RH,Resolution:0.5%RH,Accuracy:±3%RH Pressure Range:10-110kPa,Resolution:0.1hPa,Accuracy:±1hPa Output signal: RS485/SDI-12 Supply: 12-24VDC With Solar Radiation Shield and 2 meter cable included
Price €365.00
More
In stock

Follow us on Facebook