A miniature, value-priced, waterproof data logger for temperature and light monitoring applications; stores 52K measurements.  IMPORTANT INFORMATION Requires HOBOware software and either an Optic USB Base Station or a HOBO Waterproof Shuttle (U-DTW-1). HOBOware Pro is required when using the HOBO Waterproof Shuttle. See compatible items below.
All best sellers
  • PAYMENT METHODS

  • New
MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger
  • MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger
  • MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger
  • MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger
  • MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger

MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger

MX1102A

MX1102A HOBO Carbon Dioxide/Temp/RH Data Logger

Measures and records CO2 in buildings and other non-condensing environments.

Important Information

Requires either Onset's HOBOware software or a compatible mobile device or Windows computer and the HOBOconnect app.

Measures and records CO2 in buildings and other non-condensing environments. Works with our free HOBOconnect app for data access right from your mobile phone, tablet, or Windows computer when within 100 feet of the logger.

This logger also features a USB port so it can be used with a computer running HOBOware graphing & analysis software.

Description

Features

    Wireless communication via Bluetooth technology
    Six-month battery life at 5-minute CO2 logging rate
    Easy to deploy and offload using free HOBOconnect app
    Visual and audible high & low alarm thresholds
    Self-calibrating NDIR CO2 sensor technology ensures optimal accuracy and lower maintenance costs
    Patented connectivity technology

Specifications

Temperature Sensor:
Range:
    0° to 50°C
    32° to 122°F
Accuracy:
    ±0.21°C from 0° to 50°C, see manual for plot
    ±0.38°F from 32° to 122°F, see manual for plot
Resolution:
    0.024°C at 25°C , see manual for plot
    0.04°F at 77°F , see manual for plot
Drift:
    <0.1°C per year
    0.18°F per year

RH Sensor*
Range:
    1% to 90% RH (non-condensing)
Accuracy:
    ±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution:
    0.01%
Drift:
    <1% per year typical

CO2 Sensor
Range:
    0 to 5,000 ppm
Accuracy:
    ±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH (non-condensing) and 1,013 mbar
Warm-up Time:
    15 seconds
Calibration:
    Auto or manual to 400 ppm
 
    <1% of FS
Pressure Dependence:
    0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range:
    950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range:
    -305 to 5,486 m
    -1,000 to 18,000 ft
Sensing Method:
    Non-dispersive infrared (NDIR) absorption

Response Time:
Temperature:
    12 minutes to 90% in airflow of 1 m/s
    12 minutes to 90% in airflow of 2.2 mph
RH:
    1 minute to 90% in airflow of 1 m/s
    1 minute to 90% in airflow of 2.2 mph
CO2:
    1 minute to 90% in airflow of 1 m/s
    1 minute to 90% in airflow of 2.2 mph

Logger:
Radio Power:
    1 mW
    0 dBm
Transmission Range:
    Approximately 30.5 m line-of-sight
    Approximately 100 ft line-of-sight
Wireless Data Standard:
    Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range:
    0° to 50°C ; 0 to 95% RH (non-condensing)
    32° to 122°F ; 0 to 95% RH (non-condensing)
Logging Rate:
    1 second to 18 hours
Logging Modes:
    Fixed interval (normal, statistics) or burst
Memory Modes:
    Wrap when full or stop when full
Start Modes:
    Immediate, push button, date & time, or next interval
Stop Modes:
    When memory full, push button, date & time, or after a set logging period
Time Accuracy:
    ±1 minute per month at 25°C
    ±1 minute per month at 77°F
Power Source:
    4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts)
Battery Life:
    6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life.
Memory:
    128 KB (84,650 measurements, maximum)
Download Type:
    USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time:
    20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger
LCD:
    LCD is visible from 0° to 50°C;
    LCD is visible from 32° to 122°F;
    the LCD may react slowly or go blank in temperatures outside this range
Size:
    7.62 x 12.95 x 4.78 cm
    3.0 x 5.1 x 1.88 inches
Weight:
    267.4 g
    9.43 oz
Environmental Rating:
    IP50

Product Details
MX1102A
Comments (0)
Grade
No customer reviews for the moment.
16 other products in the same category:

Reference: SC-1

SC-1 Leaf Porometer Stomatal Conductance

(0)
To measure stomatal conductance using the steady state technique. SC-1 Porometer Applications Water use and water balance. Measurement of water stress. Basic research in plant physiology. Herbicide assimilation. Assimilation of ozone and other polluting agents. Tests and comparative studies. Stomatic behavior.

Reference: U30-NRC-000-10-S100-000

Brand: ONSET

HOBO U30 USB Weather Station

(0)
15 Channel Energy Monitoring and Weather Station Data Logger A rugged weather station for outdoor environmental monitoring; easily configurable for specific application needs, with up to 15 channels to collect environmental data.  Required software HOBOware Pro + CABLE-USBMB External sensors sold separately.

Reference: ME-337

ME-337 Rogowski Smart Panel Meter

(0)
BENEFIT FOR THE CUSTOMER:*Direct connection with open Rogowski coils* Three-phase/Single-phase*Phase N Current measurement*6-Rate (Manual or RTC)*Display of harmonic values from 1 to 50 (PRICE NOT INCLUDED ROGOWSKI COIL)

Reference: RX2101+SP-611

Brand: ONSET

RX2100 HOBO MicroRX Station Data Logger

(0)
MicroRX Station A rugged, easy-to-deploy, low-cost cellular solution for reliable, long-term field monitoring. Inputs for up to five plug-and-play sensors. Data access through the HOBOlink cloud platform. IMPORTANT INFORMATION External sensors must be purchased separately. Requires HOBOlink data plan, which must be renewed annually. Learn more about...

Reference: NRC-100

Brand: Meatrol

NRC-100 Thin Flexible Rogowski coil fixed with cable ties

(0)
Applications*Smart meter*Rectifier current measurement*Power quality analysis*Motor overload/short circuit protection*Current monitoring of power frequency and intermediate frequency welding machine*Medium and high voltage switchgear protection system* Remote Terminal Unit (RTU)*Synchronous Phasor Measurement Unit (PMU)*Current measurement on the...

Reference: H21-USB

Brand: ONSET

H21-USB - HOBO USB Microstation Data Logger

(0)
Features Compact size for easy deployment Weatherproof IP66 enclosure for harsh environments Direct USB offload--no need for an adapter cable Includes five Smart Sensor inputs Hinged door and integrated mounting tabs Runs for up to a year on four standard AA batteries Compatible with HOBOware and HOBOware Pro software for logger setup and graphing &amp;...

Reference: H22-001

H22-001 HOBO H22 Energy Data Logger

(0)
H22-001 HOBO H22 Energy Data Logger Monitor energy and industrial equipment with this 15-channel data logger to quickly detect and address issues relating to HVAC, machinery, and other systems. Important InformationExternal sensors sold separately. Requires HOBOware software and part # ADAPT-SER-USB interface cables. See compatible items below.

Reference: DA01

Brand: Meatrol

DA01 Integrator for Rogowski Coils

(0)
DA01 1A output Integrator -Rated input:100A,600A,1kA,3kA,6kA(only choice one point,accept OEM) -Rated output:0-1A rms, 0-100mA rms -Accuracy:±0.5% (from 1% to 100% of rated ) -Bandwidth:30Hz to 5KHz -Power supply:12V or 24V DC(Default 24VDC) -Maximum Burden 0.5Ω -Maximum power 5W

Reference: TA Sensor de temperatura

TA Outside air temperature sensor

(0)
Accurate and reliable sensor for measuring air temperature, compact and robust, made of aluminium alloy with anodized treatment to protect against salinity and oxidising agents. Fully compliant with WMO Annex 8 standards for environmental monitoring applications.

Reference: DL8M

Brand: MAE

DL8M 8 Channels Data Logger, 24 bit, Bluetooth Configuration

(0)
DescriptionDL8M is the ideal solution for all environmental or structural moniotoring in which high resolution, velocity of implementation and low costs of system management are required, together with the greatest simplicity in management and processing acquired data. DLM8 allows to briefly and easily realize indipendent systems of monitoring whose...

Reference: ME631-SD

Brand: Meatrol

ME631-SD Three-phase Power Meter

(0)
ME631-SD -Multifunction Record Meter --DIN-RAIL -Communication: MODBUS-RS485 -Power supply:85-240V -Harmonic:51THD -4GB SD card recorder -Connect:rogowski coil and 333mV Cts with VT up to 500kV -Rated current:500A,1000A,3000A,6000A(only choice one point,accept OEM) -Rated coil ratio:50mV/kA, 85mV/kA or 333mV/kA(need to be define) Record...

Follow us on Facebook