Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS9107+
Brand: iBUTTON MAXIM INTEGRATED
Reference: INTEGRADOR S10 MINI
Brand: Meatrol
TR71A2
Overview
The TR71A2 is a temperature logger with two available sensor connections and can measure from -60 to 155℃. The wide range of optional sensors provides increased measurement flexibility.
The LCD screen allows the simultaneous display of either the current values of two channels, the highest and lowest values of channel 1, or the highest and lowest values of channel 2. The ALM icon on the LCD alerts the user of the occurrence of an alarm.
Use the wireless LAN feature to auto-upload data to the cloud for anytime anywhere access and get warning notices. Bluetooth communication allows you to view data, create reports and make settings from a smartphone or tablet. Connect to a PC with a USB cable to download recorded data, create reports and make setting changes.
The software application used with the TR71A2 has a "Vaccine Mode", which meets or exceeds CDC requirements for VFC, and is useful for monitoring and recording vaccine temperatures. TR71A2 is useful not only in research labs and hospitals, but also in homes, offices, and other industries.
TR71A2 Operational Differences by Measurement Mode | ||
Normal Mode | Vaccine Mode | |
Max/Min Values | Max/Min temperature reading since the start of recording or reset (via buttons or software/app) | Max/Min recorded value since the start of recording or reset (via buttons or software/app) |
Warning Judgment Time | 30 sec to 60 min (9 selections) | 0 sec. |
A warning will be issued when a measurement exceeds the set threshold value or a sensor error occurs for longer than the set judgment time. | If a recorded value exceeds the set threshold value or if a sensor error occurs, a warning will be issued. | |
Warning Display [ALM] Icon | Warning alarms for exceeding a set upper and lower limit and for sensor errors will both disappear when the warning condition is resolved. | Warning alarms for exceeding a set upper and lower limit will not disappear even after a value returns to within the threshold range. Warning alarms for sensor errors will disappear upon return to normal. |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: ST2424
Brand: MAE
Reference: H21-USB
Brand: ONSET
Reference: CRONOSONIC
Brand: MAE
Reference: LAQUAtwin pH-11
Brand: HORIBA LAQUAtwin
Reference: U2422
Brand: COMET
Reference: MX2204
Brand: ONSET
Reference: ZSC
Brand: METER GROUP
Reference: MX2302A
Brand: ONSET
Reference: DS1922L-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: ME531
Brand: Meatrol
Reference: DLI-400
Brand: Apogee Instruments
Reference: Mi550
Brand: Meatrol
Reference: DLI-600
Brand: Apogee Instruments
Reference: Wet&Dry + QA-PS20W
Brand: NESA
Reference: U24-002-C
Brand: ONSET
check_circle
check_circle