Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Reference: DS9107+
Brand: iBUTTON MAXIM INTEGRATED
Reference: INTEGRADOR S10 MINI
Brand: Meatrol
To measure stomatal conductance using the steady state technique.
SC-1 Porometer Applications
Water use and water balance.
Measurement of water stress.
Basic research in plant physiology.
Herbicide assimilation.
Assimilation of ozone and other polluting agents.
Tests and comparative studies.
Stomatic behavior.
Accurate and reliable measurements of stomatal conductance
Stomatal conductance is one of the most difficult parameters to measure in the soil-plant-atmosphere continuum.
With the SC-1 Porometer, precise stomatal conductance measurements are obtained quickly and easily.
The SC-1 Porometer measurements are based on steady state theory and a continuous process of research, improvement and development carried out by the METER Group team over the last 15 years.
Stomatal conductance is measured after placing a leaf in series with two known conductance elements (humidity sensors).
By measuring the humidity difference from these humidity sensors, the flow of water vapor is known.
The leaf conductance values are calculated from these variables, since the humidity is known at three points: on the leaf and at the two humidity sensors.
Quick measurements with the SC-1 porometer
Stomatal conductance measurements are obtained in thirty seconds.
It is necessary to calibrate the equipment in the field and whenever the environmental conditions during sampling change.
The calibration takes just a few minutes. The SC-1 Porometer is a portable, battery-operated device that incorporates a simple user menu.
The equipment is light, has memory for more than 4000 data and allows downloading via cable (USB cable and management program included).
Readings can be recorded as conductance or resistance.
Technical Specifications of the SC-1 Porometer |
|
Precision | 10% of the measurement |
Conductance measurement range | 0 to 1000 mmol m2 s-1 |
Environmental conditions for operation | 5 to 40°C, 0 to 100% RH, with desiccant chamber |
Power | Four "AA" batteries |
Battery life | 3 years (standby battery consumption <50 µA) |
Measurement units | µmol m2 s-1, m2/s mol–1, s/m |
Memory | 4095 measurements. Flash memory |
Communication interface | USB Cable |
Diameter of the measuring chamber | 6.35mm |
Sensor head cable length | 1.2m |
Desiccant | DrieRlte, particle size 10-20 mm |
Measurement time | 30 s (in automatic mode) |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: LI19
Brand: Hukseflux
Reference: UX100-003
Brand: ONSET
Reference: LAQUAtwin pH-11
Brand: HORIBA LAQUAtwin
Reference: RX3004+SP-611
Brand: ONSET
Reference: K-600M
Brand: BOSEAN
Reference: ZSC
Brand: METER GROUP
Reference: MX2305
Brand: ONSET
Reference: Mi550
Brand: Meatrol
Reference: HF03-LI19
Brand: Hukseflux
Reference: TR71A2
Brand: TandD
Reference: MX2202
Brand: ONSET
Reference: TR45
Brand: TandD
Reference: TCR24
Brand: MAE
Reference: ME531
Brand: Meatrol
Reference: Wet&Dry + QAS22024
Brand: NESA
check_circle
check_circle