- New
Reference: 10HS ECHO - 5Mts
Reference: 10HS ECHO - 5Mts
Reference: BASE-U-4
Reference: UA-002-64
Brand: ONSET
Reference: VH400-2M
Brand: VEGETRONIX
Reference: DS1922E-F5
Brand: iBUTTON MAXIM INTEGRATED
Industrial Class A pyranometer with heating and tilt sensor
The SR300-D1 is optimized for use in photovoltaic power plants. The sensor meets industrial grade requirements for sensor surge immunity and installation safety. The SR300-D1 is designed for use where maximum measurement accuracy and reliability are required.
Measurand | hemispherical solar radiation,sensor tilt angle (3 components x, y and z) |
ISO 9060:2018 classification | spectrally flat Class A pyranometer |
IEC 61724-1:2021 compliance | meets Class A PV monitoring system requirements |
IEC 61724-1:2021 compliance | for solar irradiance for all locations and climatic conditions - for single axis tracker and pyranometer tilt angle measurement |
Dome protector | included (model DP01) |
Status LED | power & communication |
Instrument diagnostics | leakage, tilt, rotation, heating, internal humidity |
Heating | included |
Calibration certificate | included (content limited according to ISO/IEC 17025, section 7.8.1.3) |
Temperature response test of individual instrument | report included |
Temperature response | < ± 0.4 % (-30 to +50 °C) |
Directional response test of individual instrument | report included to 95 ° |
Accelerometer test of individual instrument | report included |
Tilt measurement uncertainty | ± 1 ° (0 to 180 °) (-30 to +50 °C) |
Standard cable length (not included) | 3 m |
EMC and Surge immunity * | : |
Equipment classification | Industrial Equipment |
Surge Immunity | Level 2, test level 1 kV |
with optional SPD01 | Level 4, test level 4 kV |
Electrical Safety in the workplace | : |
Safety compliance | EU Low Voltage Directive (2014/35/EU) / USA National Electric Code (NFPA70) |
Earthing terminal | included on instrument |
Operation in 3 power modes ** | : |
Norma -heated, ventilated | < 3 W |
Medium -unheated, ventilated | < 1 W |
Low -unheated, unventilated | < 0.5 W |
Digital communication | : |
Communication protocol | Modbus RTU |
RS-485 isolation voltage | 1.5 kV |
Hardware interface | 2-wire RS-485 |
Options
We offer accessories for use with the SR300-D1, including electrical and mounting hardware options.
• SPD01 Surge Protection Device (for 1 to 3 instruments) for cables longer than 3 meters and to upgrade surge protection to Level 4
• PID01 Pyranometer Isolation Disk, which electrically isolates the instrument from the mounting platform, spring-loaded for easy leveling
• LM01 Spring-loaded Leveling Stand; a handy stand for easy mounting, leveling, and exchanging instruments on flat surfaces
• TLM01 Pipe Leveling Stand with a set of bolts
• Calibration Certificate including customer name and contact information
• DP01 Dome Guard, 5-piece set
• AMF03 Albedometer Attachment
• PMF01 and PFM02 Mounting Accessories
SR300-D1 – “Industrial Grade” Solar Radiation Monitoring¡
Hukseflux introduces “industrial grade” solar radiation monitoring. The fully digital heated pyranometer SR300-D1 is designed to measure solar radiation with the highest reliability and measurement accuracy. The SR300-D1 is the successor to our SR30-M2-D1 pyranometer, which is globally recognised as the ideal instrument for use in monitoring the performance of photovoltaic systems.
The SR300-D1 still offers the measurement accuracy of the SR30. It may look like it, but in many ways the SR300-D1 is a completely new instrument, custom-designed for use in photovoltaic monitoring systems.
The SR300-D1 meets industrial grade requirements for immunity, emissions, electricity, environment and safety for use in outdoor industrial environments, greatly improving measurement reliability.
Ease of use is further enhanced with expanded features and diagnostics. Monitoring PV Systems with the SR300-D1 Industrial Pyranometer
Monitoring PV System Performance – Meets IEC 61724-1 Class A
The SR300-D1 meets IEC requirements for monitoring the performance of “Class A” PV systems, with no additional accessories required. Features:
Built-in heater for dew and frost mitigation
Accredited pyranometer calibration within required uncertainty limit
Tilt sensor calibrated to ±1° accuracy, as required for single-axis tracker fault detection and pyranometer tilt measurement
Immunity to High Voltages and Currents – Surge
The SR300-D1 is tested and rated for industrial environments in accordance with IEC 61326-1 and IEC 61000-6-2. When designing a measurement system, SR300-D1 users can achieve various levels of immunity.
Using the optional SPD01 surge protection device, this immunity can be increased to 4 kV. Up to 3 pyranometers can be protected with a single SPD01. A third-party SPD with similar specifications can be used instead.
To achieve the required immunity level for a given installation, some general system components must be included, such as:
• lightning protection system
• grounding network
• external surge protection in addition to the native protection of the integrated sensor
RS-485 Isolation
The RS-485 interface of the industrial pyranometers is galvanically isolated from the internal electronics and the instrument body. Both isolation barriers are rated at 1.5 kV. This contributes to reliable operation, flexibility in system design, and lower integration costs for all industrial pyranometers.
Electrical Safety in the Workplace
A photovoltaic power plant is a potentially hazardous work environment. To comply with safety regulations, the SR300-D1 features a dedicated grounding terminal for protective earth connection. When the pyranometer is isolated from the mounting platform, it must still be properly grounded through this terminal. The SR300-D1 enables system designers to comply with safety regulations. These are typically based on EU and US electrical safety standards, such as:
• EN-50110 Operation of Electrical Installations
• NFPA 70 National Electrical Code (NEC)
Tilt angle measurement
For PV systems with single-axis trackers, IEC 61724-1:2021 Class A systems also require a tilt angle measurement. The sensor used for this is an accelerometer. Every SR300-D1 accelerometer is individually calibrated, and temperature compensated from -30 to +50 °C, resulting in a high accuracy measurement in compliance with the required accuracy of ± 1 °. The acceleration components x, y and z can separately be read out to provide additional information about the instrument orientation.
Heated pyranometer that mitigates dew and frost
Heated for high data availability, operation in 3 power modes
SR300-D1 includes a heater. Heating mitigates dew and frost, leading to high data availability.
SR300-D1 can be operated in 3 power modes. Overall performance in all 3 modes complies with ISO 9060 Class A classification criteria. This allows users to conserve power and continue the measurement, also when the system operating power is limited.
• normal, < 3 W heated / ventilated for optimal dew and frost mitigation
• medium, < 1 W unheated / ventilated for high accuracy measurement, when dew and frost are not an issue
• low, < 0.5 W unheated / unventilated to save power
Heating counters frost and dew deposition. In the picture on the right you see a clear difference between a heated and non-heated pyranometer.
Remote diagnostics
In addition to solar irradiance, SR300-D1 outputs several alerts and measurements for remote use, most importantly:
• alert: instrument leakage
• alert: change of tilt and rotation
• alert: heating malfunction
• internal humidity
• internal pressure
Remote diagnostics reduces the need for (un)scheduled field inspection.
On-site diagnostics: status LED
The status LED provides visual feedback to a local operator. On-site, users have immediate information on instrument power and data traffic. This is especially useful during installation and field inspections.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: Y022H
Brand: HORIBA LAQUAtwin
Reference: LAQUAtwin pH-11
Brand: HORIBA LAQUAtwin
Reference: TR-55i-V
Brand: TandD
Reference: LS155
Brand: LINSHANG
Reference: RK300-09 SO2
Brand: RIKA SENSORS
Reference: U22-001
Brand: ONSET
Reference: S-RGA-M002
Brand: ONSET
Reference: PX3PLN02S
Brand: VERIS
Reference: LS170
Brand: LINSHANG
Reference: SRC-100
Brand: Meatrol
Reference: M2 T
Brand: tempmate
Reference: SU-220
Brand: Apogee Instruments
Reference: H722HC
Brand: VERIS
Reference: S1SA1S
Brand: MAE
Reference: FS4309
Brand: FUEHLER SYSTEME
Reference: BH90E
Brand: BOSEAN